TROUBLESHOOTING
Service Diagnosis
If one of the following errors have occurred, contact local distributor for assistance.
• The error lamp of the outdoor unit flashing rapidly even though shut down and restart of the system is carried out.
• The remote controller displays error codes or the buttons on the controller do not work.
• The safety fuse blows frequently or the circuit breaker trips frequently.
• Obstacles and water enter the unit.
• Water leaks from indoor unit.
If system does not operate properly besides cases or malfunctions mentioned above, use the following procedure to check system.
Table 34 —Troubleshooting Procedures
Symptoms
Causes
Solution
Unit will not start
• Power supply failure
• Power switch is off
• Fuse burned out
• Recover the power supply
• Switch on the power
• Replace the fuse
Fan operates, no cooling or
heating
• Temperature is not set correctly
• Time delay in compressor operation
• Set the temperature correctly
• Wait for at least three minutes for compressor to come back
on
Unit starts or stops frequently
• Incorrect refrigerant charge
• Air or other gas in the refrigerant circuit
• Improper voltage
• Check for leaks and refrigerant charge
• Vacuum and recharge refrigerant
• Voltage measured between L1 and L2 should be 187 to 253
volts
No cooling effect
• Heat exchanger of ODU or IDU is dirty or blocked
• Air filter of indoor unit is dirty
• Outdoor temperature is too high
• Lack of refrigerant
• Clean the heat exchanger and eliminate any obstacles
• Clean or replace the air filter
• Normal control
• Check for leaks and refrigerant charge
No heating effect
• Lack of refrigerant
• Check for leaks and refrigerant charge