120
Table 130 —38VMA072RDS5-1 (RDS6-1)
Tc: Total Capacity PI: Power Input
Combination
Outdoor
air temp.
Indoor air temp. °FDB
61
65
68
70
72
75
Tc
PI
Tc
PI
Tc
PI
Tc
PI
Tc
PI
Tc
PI
%
°FDB
°FWB
MBH
kW
MBH
kW
MBH
kW
MBH
kW
MBH
kW
MBH
kW
60
-12.6
-13
52.0
6.5
51.8
6.8
50.2
6.9
48.0
6.7
45.8
6.5
42.4
6.3
-9
-9.4
58.0
7.0
53.6
6.8
50.2
6.6
48.0
6.4
45.8
6.3
42.4
6.0
-3.64
-4
58.0
6.8
53.6
6.6
50.2
6.4
48.0
6.2
45.8
6.1
42.4
5.8
-1.84
-2.2
58.0
6.7
53.6
6.5
50.2
6.3
48.0
6.1
45.8
6.0
42.4
5.7
5.5
5
58.0
6.3
53.6
6.1
50.2
5.9
48.0
5.8
45.8
5.6
42.4
5.4
9.5
8.5
58.0
6.1
53.6
5.9
50.2
5.7
48.0
5.6
45.8
5.4
42.4
5.2
13
12
58.0
5.8
53.6
5.7
50.2
5.5
48.0
5.4
45.8
5.3
42.4
5.0
15
14
58.0
5.7
53.6
5.6
50.2
5.4
48.0
5.3
45.8
5.1
42.4
4.9
17
15.5
58.0
5.6
53.6
5.5
50.2
5.3
48.0
5.2
45.8
5.1
42.4
4.9
19
18
58.0
5.5
53.6
5.3
50.2
5.2
48.0
5.1
45.8
4.9
42.4
4.7
22
20
58.0
5.4
53.6
5.2
50.2
5.1
48.0
5.0
45.8
4.8
42.4
4.6
26
24
58.0
5.2
53.6
5.0
50.2
4.9
48.0
4.7
45.8
4.6
42.4
4.4
30
28
58.0
4.9
53.6
4.8
50.2
4.6
48.0
4.5
45.8
4.4
42.4
4.2
35
32
58.0
4.7
53.6
4.6
50.2
4.4
48.0
4.3
45.8
4.2
42.4
4.0
39
36
58.0
4.5
53.6
4.3
50.2
4.2
48.0
4.1
45.8
4.0
42.4
3.8
44
40
58.0
4.2
53.6
4.1
50.2
4.0
48.0
3.9
45.8
3.8
42.4
3.6
47
43
58.0
4.1
53.6
3.9
50.2
3.8
48.0
3.7
45.8
3.6
42.4
3.5
51
47
58.0
3.8
53.6
3.7
50.2
3.6
48.0
3.5
45.8
3.4
42.4
3.3
54
50
58.0
3.7
53.6
3.5
50.2
3.4
48.0
3.4
45.8
3.3
42.4
3.1
57
53
58.0
3.5
53.6
3.4
50.2
3.3
48.0
3.2
45.8
3.1
42.4
3.0
60
56
58.0
3.3
53.6
3.2
50.2
3.1
48.0
3.0
45.8
3.0
42.4
2.8
50
-12.6
-13
48.4
6.3
44.7
6.1
41.8
5.9
40.0
5.8
38.2
5.7
35.3
5.4
-9
-9.4
48.4
6.0
44.7
5.8
41.8
5.7
40.0
5.5
38.2
5.4
35.3
5.2
-3.64
-4
48.4
5.8
44.7
5.6
41.8
5.5
40.0
5.4
38.2
5.3
35.3
5.0
-1.84
-2.2
48.4
5.7
44.7
5.6
41.8
5.4
40.0
5.3
38.2
5.2
35.3
5.0
5.5
5
48.4
5.4
44.7
5.2
41.8
5.1
40.0
5.0
38.2
4.8
35.3
4.7
9.5
8.5
48.4
5.2
44.7
5.0
41.8
4.9
40.0
4.8
38.2
4.7
35.3
4.5
13
12
48.4
5.0
44.7
4.9
41.8
4.7
40.0
4.6
38.2
4.5
35.3
4.4
15
14
48.4
4.9
44.7
4.8
41.8
4.6
40.0
4.5
38.2
4.4
35.3
4.3
17
15.5
48.4
4.8
44.7
4.7
41.8
4.6
40.0
4.5
38.2
4.4
35.3
4.2
19
18
48.4
4.7
44.7
4.6
41.8
4.5
40.0
4.4
38.2
4.3
35.3
4.1
22
20
48.4
4.6
44.7
4.5
41.8
4.4
40.0
4.3
38.2
4.2
35.3
4.0
26
24
48.4
4.4
44.7
4.3
41.8
4.2
40.0
4.1
38.2
4.0
35.3
3.8
30
28
48.4
4.2
44.7
4.1
41.8
4.0
40.0
3.9
38.2
3.8
35.3
3.7
35
32
48.4
4.0
44.7
3.9
41.8
3.8
40.0
3.7
38.2
3.6
35.3
3.5
39
36
48.4
3.8
44.7
3.7
41.8
3.6
40.0
3.5
38.2
3.5
35.3
3.3
44
40
48.4
3.6
44.7
3.5
41.8
3.4
40.0
3.4
38.2
3.3
35.3
3.1
47
43
48.4
3.5
44.7
3.4
41.8
3.3
40.0
3.2
38.2
3.1
35.3
3.0
51
47
48.4
3.3
44.7
3.2
41.8
3.1
40.0
3.0
38.2
3.0
35.3
2.8
54
50
48.4
3.1
44.7
3.0
41.8
3.0
40.0
2.9
38.2
2.8
35.3
2.7
57
53
48.4
3.0
44.7
2.9
41.8
2.8
40.0
2.8
38.2
2.7
35.3
2.6
60
56
48.4
2.8
44.7
2.8
41.8
2.7
40.0
2.6
38.2
2.6
35.3
2.5
Содержание 38VMA072RDS5-1
Страница 24: ...24 Refrigerant Circuit Diagram Fig 7 38VMA072 096 120RDS Models...
Страница 25: ...25 Refrigerant Circuit Diagram Cont Fig 8 38VMA144RDL 168 196 216 240RDS Models...
Страница 26: ...26 Refrigerant Circuit Diagram Cont Fig 9 38VMA240RDL 264 288 312 336RDS Models...
Страница 55: ...55 Equipment Selection SELECTION FLOW CHART Fig 53 Selection Flow Chart...