Содержание 6105

Страница 1: ......

Страница 2: ... CARON we are committed to continuous quality improvement Our goal is to supply our customers with highly reliable equipment at a fair price In order to openly monitor our performance we would appreciate your feedback on our products and services If you have questions or any suggestions for improvement based on the installation or operation of the equipment you have purchased please contact our se...

Страница 3: ...anualH Rev M 07 16 182 14 2021 Page 3 of 34 Revision Log Version Date Description K 08 02 17 Updated consistency between all manuals L 11 15 17 Added door heat and light connection instructions M 07 16 18 Updated PM Kit info ...

Страница 4: ...o initiation of any such repairs NOT COVERED Calibration of control parameters Improper installation including electrical service gas and water supply tubing gas supplies room ventilation unit leveling facility structural inadequacies or ambient conditions that are out of specification Cost of express shipment of equipment or parts Any customer modifications of this equipment or any repairs undert...

Страница 5: ...on of any such repairs NOT COVERED Calibration of control parameters Improper installation including electrical service gas and water supply tubing gas supplies room ventilation unit leveling facility structural inadequacies or ambient conditions that are out of specification Cost of express shipment of equipment or parts Any customer modifications of this equipment or any repairs undertaken witho...

Страница 6: ...ater connections 10 OPERATION 12 Start up 12 Temperature set point 13 Countdown timer 14 Humidity set point 15 Low water level alarm 15 Viewing light 17 8 CALIBRATION 19 7 MAINTENANCE 318 Routine maintenance 318 Brief Troubleshooting 519 Spare Replacement Parts 6 Electrical Schematic 27 21 Spare Replacement Parts 29 Declaration of Conformity 30 2 ...

Страница 7: ...ed temperature range Humidity Control 3 Interior Dimensions 24 W x 18 D x 22 H Exterior Dimensions 28 W x 26 D x 37 H Work Space 5 ft3 Shelf Work Area 5 3 ft2 shelf plus bottom Electrical 208 230V 15 A 60 Hz Model 6105 2 208 230V 15 A 50 Hz Model 6105 3 Specifications are based on exhaust air vent closed Features Digital temperature and humidity display PID control 1 16DIN set point process value ...

Страница 8: ...NATIONAL SYMBOLS AND DEFINITIONS WARNINGS Use eye protection gloves and aprons if exposure to hazardous materials could occur Warning of hazardous area Warning of dangerous electric voltage Earth ground protective conductor Local government may require proper lamp disposal ...

Страница 9: ... www caronproducts com Chamber Location The chamber must be located in a dry clean and level area Allow a 2 inch 51 mm clearance from the back of chamber for proper air circulation Locate the chamber in an area out of direct sunlight and away from heating and cooling ducts The figure below shows the exhaust port on the back of the chamber Install rubber stopper vent into port and press in firmly M...

Страница 10: ...warranty Door Heat and Light Connection Locate the connection input on the bottom right of the door Be sure the corresponding yellow connector is properly inserted Note The black shroud on the yellow connector must be pulled back for insertion and then pushed forward once connected to lock Carboy water bottle BTL101 optional Mount the universal carboy holder either on the top of the chamber or on ...

Страница 11: ...able The system provides continuous clean filtered water to the chamber s humidity injection system collects and recycles the condensate that forms in the base of the chamber Refer to instructions with the CRSY102 for connection details Use fittings provided with 6105 to connect to CRSY102 Install Shelf Hanging Rails Insert both shelf tracks into the chamber see picture below Each unit is equipped...

Страница 12: ... see installation section Turn on unit by pressing the power switch The power on indicator light temperature and timer displays will illuminate Air should be gently circulating internally Control panel layout Temperature controller Humidity control enable Countdown timer Light switch Humidity controller Power switch Power On indicator light Temperature and timer displays ...

Страница 13: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 13 of 34 ...

Страница 14: ...ll only control temperature within the specified range Controller Parameters The Advance and Infinity Home buttons are for diagnostics purposes Pressing the Advance button will display the amount of time in percent that the heaters are on Press the Infinity Home button to return to the temperature display The unit is capable of reaching temperatures that could result in burns Always wear protectiv...

Страница 15: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 15 of 34 ...

Страница 16: ...1 Set total countdown time to desired value using the four up and down arrow buttons 2 Press the start button 3 When the time remaining reaches 0 00 the alarm buzzes and display turns red for 3 seconds 4 Press the reset button the time remaining resets to the total countdown time Press the reset button at any time to stop the countdown Timer just reached 0 00 alarm is buzzing 3 seconds after timer...

Страница 17: ...n the inside For fingerprint development processes that do not require humidity temperature control only the humidity switch should be off Turning the humidity enable switch off drains the steam generator Low water level alarm The low water level alarm light will illuminate if the humidity control switch is enabled and after 30 seconds the internal steam generator does not fill properly See troubl...

Страница 18: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 18 of 34 ...

Страница 19: ...oor or rear vent The chamber will only control humidity within the specified range Controller Parameters The Advance and Infinity Home buttons are for diagnostics purposes Pressing the Advance button will display the amount of time in percent that the heaters are on Press the Infinity Home button to return to the temperature display Advance button Humidity set point Actual humidity Up button Down ...

Страница 20: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 20 of 34 Viewing light To illuminate the interior turn on the light switch If lighting does not come on see troubleshooting guide Light switch ...

Страница 21: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 21 of 34 ...

Страница 22: ...ceptable range use the following steps to adjust the controller to be within the acceptable range The difference will be used as the offset below 3 To make the adjustment to controllers press and hold the infinity and advance keys simultaneously for 6 seconds Once the Programming Page has come up release the keys Using the advance key scroll through until the P4 parameter is displayed Use the up a...

Страница 23: ...M 07 16 182 14 2021 Page 23 of 34 6 Repeat Step 2 to return to P4 of the Programming Page Use the up and down keys to return the setting from CAL to NONE Press the infinity key once to save the setting and return to the main screen 5 5 ...

Страница 24: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 24 of 34 ...

Страница 25: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 25 of 34 5 ...

Страница 26: ...tor or CARON service department at www caronproducts com When contacting CARON please provide model number and serial number Routine Maintenance Routine chamber maintenance is necessary to keep the chamber working properly The recommended chamber maintenance schedule is a Clean interior chamber as needed b If the humidity control portion of the chamber is going to be unused for 20 days the small i...

Страница 27: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 27 of 34 ...

Страница 28: ... 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 28 of 34 Here is a list of PM Kits that are available for models and accessories covered in this manual Model PM Kit 6105 2 PM BOTL101 6105 3 PM BOTL101 ...

Страница 29: ...ication range Is the ambient temperature no more than 25ºC Turn unit off and open door for 1 hour Humidity controller is blank temperature controller is illuminated Is the humidity enable switch on Unit won t reach humidity set point Is the rear vent closed Is the door closed and latched Is the low water level alarm light on Is there adequate water supply Can air flow freely throughout the chamber...

Страница 30: ...itch off open door and set temperature to 100ºC for 1 hour to dry out the chamber Is water present in exhaust vent Remove stopper and let water drain out Interior lights won t come on Are lights turned on Is the connector on the bottom of the door switch connected see below Glass fogs up on inside Is the humidity switch on Is the connector on the bottom of the door switch connected see picture Is ...

Страница 31: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 31 of 34 Electrical Schematic ...

Страница 32: ...Model 6105 Operations ManualH Rev M 07 16 182 14 2021 Page 32 of 34 ...

Страница 33: ...T LGT 143 DOOR LIGHT Temperature Related Part Number Description HTR 143 AIR HEATER RMT 114 SNAP DISK 225 F RMT 115 THERMAL FUSE 169 C RTD 101 TEMPERATURE SENSOR REL 103 HEATER SOLID STATE RELAY Humidity Related Part Number Description HUM 114 RH SENSOR SOL 133 HUMIDIFICATION SOLENOLD SOL 135 DRAIN SOLENOLD LEV 106 STEAM GENERATOR LEVEL SWITCH HTR 144 STEAM GENERATOR HEATER REL 103 HUMIDITY SOLID ...

Страница 34: ...levant section s of the normalized standards and related documents shown 89 336 EEC Electromagnetic Compatibility Directive EN 61326 1997 Laboratory Equipment Immunity Measurement Control requirements EN 61000 3 2 2000 Limits for harmonic current emission EN 61000 4 2 1995 Electrostatic Discharge EN 61000 4 3 1995 Radiated Susceptibility EN 61000 4 4 1995 Electrical Fast Transient EN 61000 4 5 199...