2050 Operations Manual 

Rev L    2/2/2018 

Page 7 of 22 

 

 

 

 

 

 

EQUIPMENT INTERNATIONAL LIMITED WARRANTY 

 

Please review this section before requesting warranty service.  At CARON, one of our primary goals is 
to provide customers with high levels of personal service and top quality products, delivered on time, 
backed by technical service and supported for the life of the product. 

 

Before contacting your distributor for warranty service, please be aware that there are repairs 
that are not covered under warranty.   
 
WARRANTY DEFINED 
Caron Products & Services, Inc. (herein after CARON) hereby warrants that equipment manufactured 
by  CARON  is  free  from  defects  in  materials  and  workmanship  when  the  equipment  is  used  under 
normal operating conditions in accordance with the instructions provided by CARON. 
 
COVERED: 

  Parts for a period of two (2) years from date of shipment. 

  Any  part  found  defective  will  be  either  repaired  or  replaced  at  CARON's  or  their  authorized 

representative’s discretion. Parts that are replaced will become the property of CARON. 

  If  CARON  or  their  authorized  representatives  determine  that  the  customer's  unit  requires  further 

service,  CARON  or  the  representative  may,  at  its  sole  discretion,  provide  a  service  technician  to 
correct the problem, or require the return of the equipment to the an authorized service depot.   

  CARON  or  their  authorized  representative  will  have  the  right  to  inspect  the  equipment  and 

determine  the  repairs  or  replacement  parts  necessary.    The  customer  will  be  notified,  within  a 
reasonable time after inspection, of any costs incurred that are not covered by this warranty prior 
to initiation of any such repairs. 

 
NOT COVERED: 

  Calibration of control parameters. 

  Improper installation; including electrical service, gas and water supply tubing, gas supplies, room 

ventilation,  unit  leveling,  facility  structural  inadequacies  or  ambient  conditions  that  are  out  of 
specification. 

  Cost of express shipment of equipment or parts.  

  Any customer modifications of this equipment, or any repairs undertaken without the prior written 

consent of CARON, will render this limited warranty void. 

  CARON  and  their  representative  are  not  responsible  for  consequential,  incidental  or  special 

damages; whether shipping damage or damages that may occur during transfer to the customer’s 
point of use. When the equipment is signed for at the customer’s site, ownership is transferred to 
the customer. Any damage claims against the shipping company become the responsibility of the 
customer.  

  Repairs  necessary  because  of  the  equipment  being  used  under  other  than  normal  operating 

conditions or for other than its intended use. 

  Repair due to the customer's failure to follow normal maintenance instructions. 

  Parts considered consumable; including: light bulbs, filters, gases, etc. 

  Damage from use of improper water quality. 

  Damage from chemicals or cleaning agents detrimental to equipment materials. 

  Force Majeure or Acts of God. 

Содержание 2050

Страница 1: ......

Страница 2: ...e are committed to continuous quality improvement Our goal is to supply our customers with highly reliable equipment at a fair price In order to openly monitor our performance we would appreciate your feedback on our products and services If you have questions or any suggestions for improvement based on the installation or operation of the equipment you have purchased please contact our service de...

Страница 3: ... Operations Manual Rev L 2 2 2018 Page 3 of 22 Revision Log Version Date Description J 06 02 14 Added condenser filter K 08 02 17 Updated consistency between all manuals L 02 02 18 Consolidated terminology ...

Страница 4: ... the Circulator Emptying the Circulator Operation 12 Changing the Temperature Setpoint Changing the Low Temperature Tracking Alarm Level Changing the High Temperature Tracking Alarm Level Calibration 15 Alarms 16 Low Level Alarm Temperature Tracking Alarms Temperature Sensor Error High Temperature Safety Preventative Maintenance 17 Specifications 18 Electrical Schematics 19 Troubleshooting 20 Spar...

Страница 5: ...the right to inspect the equipment and determine the repairs or replacement parts necessary The customer will be notified within a reasonable time after inspection of any costs incurred that are not covered by this warranty prior to initiation of any such repairs NOT COVERED Calibration of control parameters Improper installation including electrical service gas and water supply tubing gas supplie...

Страница 6: ...N makes no other warranties express or implied of merchantability fitness for a particular purpose or otherwise with respect to the goods sold under this agreement This warranty cannot be altered unless CARON agrees to an alteration in writing and expressly stated herein shall be recognized to vary or modify this contract Ohio Law governs this warranty ...

Страница 7: ...ive will have the right to inspect the equipment and determine the repairs or replacement parts necessary The customer will be notified within a reasonable time after inspection of any costs incurred that are not covered by this warranty prior to initiation of any such repairs NOT COVERED Calibration of control parameters Improper installation including electrical service gas and water supply tubi...

Страница 8: ... or implied of merchantability fitness for a particular purpose or otherwise with respect to the goods sold under this agreement This warranty cannot be altered unless CARON agrees to an alteration in writing and expressly stated herein shall be recognized to vary or modify this contract Ohio Law governs this warranty Caron Products Services Inc PO Box 715 Marietta OH 45750 740 373 6809 ...

Страница 9: ...ge 9 of 22 INTERNATIONAL SYMBOLS AND DEFINITIONS WARNINGS Warning of hazardous area Warning of dangerous electric voltage Earth ground protective conductor Local government may require proper disposal Help Information i Warning of hot surface ...

Страница 10: ...You have just purchased the latest technology in constant temperature circulators Before using the equipment familiarize yourself with key components of the product and thoroughly read this manual Drain Plug Lift Handle Power Switch External Circulation Connections Lid Knob Control Panel ...

Страница 11: ... an area where there is no direct airflow from heating and cooling ducts and out of direct sunlight Allow four inches of clearance on the top and back of unit for airflow DO NOT cover up the air vent holes Verify proper electrical power is available External Circulation To use the external circulation connect inlet and outlet quick disconnect fittings to circulator Be sure external loop is sealed ...

Страница 12: ...h water propylene glycol or other non flammable appropriate thermal fluid Circulator should be filled approximately 0 5 from top or until the low liquid level alarm shuts off Additional fluid may be needed after the unit is turned on to compensate for external tubing volume Operation of the unit in temperature ranges near or below 0ºC may cause the fluid to attract water into the reservoir especia...

Страница 13: ...d on Within minutes the temperature will begin to approach setpoint The circulator keypad is designed to produce a simple easy to understand user interface that is intuitive and user friendly With just a few presses of the keys the logic behind the user interface is very easy to learn and remember There are four basic keys to setup or change any parameter to be setup or changed Rotates through the...

Страница 14: ...temperature tracking alarm level is the deviation from the temperature setpoint which will cause a low temperature alarm The low temperature tracking alarm level is adjustable from 0 1 to 10 0 The default is 5 0 which indicates 5 0ºC below setpoint To change the low temperature tracking alarm level 1 Press the key twice from the main menu AL L is displayed briefly 2 Press the to increase decrease ...

Страница 15: ...8 Page 15 of 22 1 Press the key three times from the main menu AL H is displayed briefly 2 Press the to increase decrease alarm level hold for scroll 3 Press the key to save the alarm level 4 Press the key twice to return to the main menu ...

Страница 16: ...C The default is 0 0 C To enter a calibration offset 1 Press the key four times from the main menu cAL is displayed briefly 2 Press the to increase decrease the calibration offset hold for scroll 3 Press the key to save the calibration offset 4 Press the key once to return to the main menu Temperature calibration example If the circulator temperature display reads 40 0 C and the calibrated indepen...

Страница 17: ...sts the display cycles between the current temperature and the alarm condition at 1 second intervals To avoid nuisance alarms on system power up or setpoint changes the alarms are disabled for two hours or until the actual temperature gets within the alarm high and low levels Temperature Sensor Error In the unlikely event that a faulty temperature sensor is detected SErr will be displayed Both the...

Страница 18: ... poor performance Recommended Annual Maintenance Checks Disinfect all interior surfaces with a general purpose laboratory cleaning agent such as Cole Parmer G 08796 00 Vacuum or blow out fan and internal components Perform a temperature calibration R 134a refrigerant This unit contains R 134a which is a fluorinated greenhouse gas covered by the Kyoto Protocol Regulation EC No 842 2006 with a GWP o...

Страница 19: ...ead Work Area Dimensions 6 0 W x 2 0 F B x 6 5 D External Dimensions 13 5 W x 13 5 F B x 14 0 H Heater 750 Watts Safeties Over temperature shutoff and low level alarm Reservoir Capacity 1 4 gallons 5 3 liters Circulator Reservoir Lid Material Stainless steel Cabinet Material Stainless steel powder coated metal Electrical 115 60 Hz 10A 230V 50 60 Hz 5A Shipping Weight 53 lbs 24 0 kg Specifications ...

Страница 20: ...2050 Operations Manual Rev L 2 2 2018 Page 20 of 22 ELECTRICAL SCHEMATICS ...

Страница 21: ...he top of the unit clean Is the pump agitating fluid inside the reservoir Is the fluid rated for the temperature being set ie water only at temperatures above 10ºC Problem Temperature is below setpoint Has the over temperature safety shut off tripped Is the pump agitating fluid inside the reservoir Is there sufficient fluid inside the reservoir low level alarm on Problem No external circulation Ar...

Страница 22: ... 101 Refrigeration filter dryer FAN 104 Condenser fan 230V FAN 118 Condenser fan 115V FIT 101 Drain pipe plug FLTR306 Condenser Filter Replacement Kit FUS 103 Fuse 10A for 115V models FUS 104 Fuse 5A for 230V models HTR 141 Heater 115V HTR 142 Heater 230V LEV 106 Level float switch MTR 136 Pump motor QDC 101 Inlet outlet female fittings in tank top QDC 103 Male quick disconnects for external circu...

Отзывы: