CARLO GAVAZZI
17
Function
Settings
[Factory settings] shown in brackets
Press
▲
or
▼
to change
Press
✱ ▲
or
✱ ▼
to change
E.oP
Event output
[nonE]
Function can be applied to each
segment independently to trigger
an output for the full duration of
that segment. Setting blocked
unless either or both outputs SP2A
or SP3A have been configured as
an
Event Output
in Level 2 or
Level A respectively.
2d
SP2A de-energised to mark event
2E
SP2A energised to mark event
3d
SP3A de-energised to mark event
3E
SP3A energised to mark event
2d.3d
SP2A and SP3A de-energised to
mark event
2E.3d
SP2A energised SP3A de-energised
to mark event
2E.3E
SP2A and SP3A energised to mark
event
2d.3E
SP2A de-energised SP3A energised
to mark event
To Return to:
LEVL P
Press and hold
▼
To Read % Programmer memory used:
USEd
Press
✱
and
▼
together in LEVL P / ProG 1
1–100%
Memory Allocation Table
Segment type
Memory required
Ramp
4 Bytes
Ramp with Holdback
5 Bytes
Soak
2 Bytes
Step
3 Bytes
Loops (1–3)
1 Byte
Loops (4+)
2 Bytes
Call
1 Byte
Event Output
1 Byte
Program Header
1 Byte
Maximum capacity:
351 Bytes
31 Programs
126 Segments
Examples:
1. 1 program of 58 Ramps and 58 Soaks
349 Bytes
2. 4 programs of 14 Ramps and 14 Soaks
340 Bytes
3. 31 programs of 2 Ramps and 1 Soak
341 Bytes
4. 2 programs of 10 Ramps, 10 Soaks, 2 Steps and 1 loop
136 Bytes
Memory Full Indication
Should the programmer memory capacity be reached during program configuration, the
display will show ‘FULL’