background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Sx2WEB HW manual 

 
 
 
 
 

rev. 0.6, 13/07/2016 

 

 

Содержание SB2WEB24

Страница 1: ...Sx2WEB HW manual rev 0 6 13 07 2016 ...

Страница 2: ...s it contains important information regarding safety The smart house system must be used only for the usage it has been designed for Every other kind of usage is potentially unsafe The manufacturer is not responsible for improper usage The manufacturer is not responsible for the consequences of using non original spare parts This manual is subject to change without notice ...

Страница 3: ... Module SH2DSP24 29 1 4 2 How to connect the Universal Mobile Modem SH2UMMF124 31 1 5 How to connect the energy meters 32 1 6 Ethernet connection 33 1 7 Micro SD 34 1 8 Pen drive installation 35 1 9 Sizing of Carlo Gavazzi DC power supply 36 1 9 1 How to calculate the power needed 36 1 9 2 How to wire the power supply 37 2 INSTALLING THE SMART HOUSE SYSTEM 38 3 APPENDIX A RS485 NETWORK GUIDELINES ...

Страница 4: ...damage to the house and a scheduler to program all events and basic functions All this means very special automation The system also includes energy monitoring logging power water and gas consumption and the information present on the bus temperatures humidity light level All this data is available in graph form simply by using a smart device or a PC thanks to the embedded webserver Moreover the s...

Страница 5: ...d any value event coming from the many buses it can connect to Wireless and Dupline buses two RS485 ports Ethernet This master unit is also provided with an SD card and USB port to upload download data and system configurations The Sx2WEB24 is the brain of the system It collects all the information from the buses it is connected to All the field devices such as light switches input output modules ...

Страница 6: ... see Appendix A for the other termination 1 1 1 Sx2WEB24 bus description Local bus 1 This is placed in the connector on the right side and it is called the High Speed bus This bus is used to connect the Dupline generators to the Sx2WEB24 Local bus 2 This is placed in the connector on the left side and it is a USB bus used to connect to the universal mobile modem SH2UMMF14 and to the usb dongle con...

Страница 7: ...How to install a Sx2WEB system 7 The buses can be summarized as shown below N B All the connections described in the following paragraphs must be carried out without power supply ...

Страница 8: ...s that is present both on the local bus and on the terminals at the bottom of the bus generators This means that the connection is very fast and easy in a cabinet since the modules only have to be plugged together without any wiring and at the same time it is very straightforward if the bus generators have to be mounted in different cabinets Up to 7 bus generators can be connected to one Sx2WEB24 ...

Страница 9: ...How to install a Sx2WEB system 9 Example 2 The bus generators are mounted in different cabinets ...

Страница 10: ...he node to the cable stars multiple cable segments brought back to a single point or loops must not be used Cable length The maximum length of the cable is 600 metres Connection of the cable shield The shield of the RS485 cable establishes a reference voltage for the RS485 signal conductors The screen pig tails going into the terminals should be as short as possible The shield should be continuous...

Страница 11: ...stem The SH2MCG24 is powered by 15 to 30Vdc The Dupline modules in the smart house system can be divided into two groups Decentralized modules these are all the modules such as light switches PIR sensors lux sensors decentralized I O modules etc which are mounted into the wall boxes or on the wall Centralized cabinet modules these are the ones housed in the 1 DIN or 2 DIN housing for din rail moun...

Страница 12: ...eered around the Dupline bus because it can be matched to the application The routing of the cable may be in a line star ring or any combination Straight through the best place for the SH2MCG24 would be in the middle of the line Star the best place for the SH2MCG24 would be in the middle of the star Ring the best location for the SH2MCG24 is in the middle between the two farthest distant modules C...

Страница 13: ...is not recommended the table is not valid in this case The values shown in the table are also suitable for installations where the majority of the modules are placed at the beginning of the network close to the SH2MCG24 this type of connection represents the best configuration to guarantee the best performance of the system Table of cable sections Max current Consumption Cable size 0 75 mm 2 AWG 1...

Страница 14: ... not be grounded at the splicing points Splices need to be water tight to prevent the entry of water into the cable which could result in increased capacitance Note Bad splices and or splices left uncovered exposed to humid environments could create critical problems difficult to route During the installation of each module the length of external cables input output must be selected according to t...

Страница 15: ... the cable resistance and the load from bus powered modules result in an excess of voltage drop Cabinet 2 Dupline modules e g 6 SH2RE16A4 Cabinet 3 Dupline modules e g 6 SH2RE16A4 Main Cabinet Sx2WEB24 SH2MCG24 150 m Cabinet 4 Dupline modules e g 4 SH2RE16A4 150 m 170 m 170 m Cabinet 5 Dupline modules e g 6 SH2RE16A4 ...

Страница 16: ...ine modules e g 6 SH2RE16A4 Main Cabinet Sx2WEB24 SH2MCG24 150 m Cabinet 4 SH2MCG24 Dupline modules e g 4 SH2RE16A4 150 m 170 m Cabinet 5 Dupline modules e g 6 SH2RE16A4 RS485 HSBUS from first SH2MCG24 to second SH2MCG24 Network 1 Orange and green Cabinets Network 2 Red and Violet Cabinets 500 m RS 485 cable ...

Страница 17: ...ules result in an excess voltage drop and might cause the modules placed far from the Dupline generator not to work properly The SB2REP230 module is a 115 to 230 VAC powered Dupline repeater and isolator and is the ideal solution to overcome the problems described above It also allows the network design to be simplified and it can be connected to any point on the Dupline bus The picture below show...

Страница 18: ... the SB2REP230 provides the bus power supply to the modules connected to it Example 1 Sx2WEB24 SH2MCG24 MODULE A MODULE B SB2REP230 MODULE C MODULE D Note the local bus on both sides is connected to the primary side of the Dupline network so the secondary side has always to be connected to the terminals REP and REP Dupline current for Modules A and B are provided by the Dupline generator Dupline c...

Страница 19: ...ater is connected to Example 2 The example below shows the network topology SX2WEB24 SH2MCG24 SH2MCG24 SH2RE16A4 SH2RE16A4 SH2SSTRI424 SB2REP230 Modules D and E are part of the Dupline network 1 Modules A B and C are part of the Dupline network 2 Network 1 Network 2 Module A Module B Module C Module D Module E Dupline bus local bus primary Dupline side of Network 1 Dupline bus Rep Rep secondary Du...

Страница 20: ...the short circuit is removed see above neither of the Dupline sides will operate 1 2 4 4 Placing the SB2REP230 in a project To wire a Dupline repeater into a network the Dupline transparent module SH1DUPFT has to be used the terminals on the top of the SH2MCG24 are connected to the Transparent module and the Dupline repeater just has to be plugged into the local bus connector The Dupline repeater ...

Страница 21: ...A even if this value increases when a relay is switched on off in the violet cabinet the installer has placed another 6 SH2RE16A4 modules the green cabinet is 700 metres away from the violet cabinet and the repeater is placed here to boost the current and voltage which otherwise are not sufficient to supply the other relay modules placed here Example of Dupline Bus current calculation see the volt...

Страница 22: ...How to install a Sx2WEB system 22 ...

Страница 23: ...ge double word information 5 A CRC control is implemented in request and reply frames Should an error occur the bus generator resends the request until it receives a correct frame Analogue data is transmitted via the SmartDupline protocol without using digital I O channels To calculate the number of SH2MCG24 required the following points have to be taken into consideration 1 Each SH2MCG24 can driv...

Страница 24: ...ne module is given in the relevant datasheet Current consumption in the datasheet instruction manual this is always given in the Dupline Specifications of each module Dupline channel consumption in the datasheet instruction manual this is always given in the Mode of Operation section under Coding Addressing ...

Страница 25: ...the terminals at the top If more bus generators are connected in a DIN rail they do not need to be plugged next to one other and they can also be mixed with the Dupline I O modules The only rule that the installer has to take into account is that a Dupline I O module is connected to the Dupline network generated by the last SH2MCG24 at its left See picture below Example 1 SX2WEB24 SH2MCG24 SH2MCG2...

Страница 26: ...us between different rails in a cabinet the Dupline transparent module SH1DUPFT has to be used The SH1DUPFT simplifies the wiring of a smart house installation it has to be connected at the beginning of a rail row bringing the Dupline bus from the top and bottom connectors to the internal bus and vice versa Internally the three connectors are short circuited This means that the buses connected to ...

Страница 27: ...How to install a Sx2WEB system 27 Example 3 ...

Страница 28: ...t circuited the situation below must be avoided This connection must be avoided otherwise two Dupline networks will be short circuited If this should happen the system will not be damaged since the bus is protected but it will not work properly 1 3 The wireless bus WiDup Please see the manual How to install the smart house wireless system ...

Страница 29: ...n if LAN not available Only LAN 1 4 1 How to connect the USB Dongle Connection Module SH2DSP24 The SH2DSP24 is a Sx2WEB24 accessory module that provides a reliable and cost effective way to connect to the Internet by using mobile networks via a dongle modem The installer has to carry out the following procedure 1 Connect the SH2DSP24 to the left of the Sx2WEB24 controller 2 Insert the SIM into the...

Страница 30: ...dem where there is good signal reception this can be checked by connecting to the Sx tool at the bottom of the user interface there are 5 bars that indicate the field strength as shown in the picture below N B Since the USB port used by the dongle modem is the same as the one used by the USB key in the Sx2WEB24 the USB key cannot be used if the modem is already connected ...

Страница 31: ...ke sure the SIM is not protected by a PIN code should that be the case disable the protection 3 Connect the antenna 4 Connect the 24VDC power supply 5 Configure it by means of the Sx tool software SH2UMMF124 SH2WEB24 Recommendation Place the modem where there is good signal reception this can be checked by connecting to the Sx tool at the bottom of the user interface there are 5 bars that indicate...

Страница 32: ...ved in an XLSX or CSV file and can be downloaded by using the Sx tool or the webserver of the Sx2WEB24 accessing it with a PC An example of the connection between an energy meter and the Sx2WEB24 is shown below Different types of energy meter can be mixed and they can also have different baud rate see the Sx tool software manual for more details about how to configure the Sx2WEB24 to manage them N...

Страница 33: ...tware manual The LAN connection can be used to connect the Sx2WEB24 to an Ethernet network when it has to be connected to other devices over TCP IP such as the BTM Tx 24 display The TCP IP device can be connected directly to the Sx2WEB24 with a peer to peer connection by using fixed IP see the Sx tool manual to configure a fixed IP The TCP IP devices can be connected to the Sx2WEB24 via a router b...

Страница 34: ... the Micro SD memory card 2 Insert the Micro SD card making sure it is not write protected and it is correctly formatted FAT32 3 Close the flap Warning if the flap is not properly closed Sx2WEB24 will not enable any writing or reading operation flap closing is verified by a micro switch located under the flap 4 As soon as the flap is closed Sx2WEB24 will install the newly inserted memory card and ...

Страница 35: ... of the Pen Drive memory 2 Insert the Pen drive making sure it is not write protected and it is correctly formatted FAT32 3 As soon as you have inserted the Pen drive Sx2WEB24 will install the newly inserted memory and update the IP address While the installation and writing operations are under way the front USB LED blue will blink Warning disconnecting the Pen drive during the writing stage will...

Страница 36: ...le for AC motor 3 0 W SH2INDI424 Digital input module 0 4 W SH2SSTRI424 Solid state relay output module 0 4W SH2D10V424 1 to 10V dimmer 0 4 W SH2UMMF124 Universal mobile modem 5 0 W The suggested families are SPDT24xx SPM3241 SPM4241 SPM5 and SPM5B battery charger According to the power required the right models has to be selected 1 9 1 How to calculate the power needed To calculate the required p...

Страница 37: ...commissioning Recommendations 1 Use a battery back up system to avoid switching off the installation if a power down should occur 2 Be careful to have a total current not greater than 3A on the power supply if using the in out terminals since the maximum current that the internal connections can withstand is 3A If Dc motors are used to control roller blinds or windows do not supply them from the s...

Страница 38: ...M door activity blue USB LED indicating the presence of a USB device and red Status LED at the first start up it will be ON indicating that no configuration is present or when it is connected to a PC via the Sx tool When connecting the network cable the Ethernet port LEDS will also light up When switching on the SH2MCG24 the following LEDs will light up on the front panel green ON LED indicating t...

Страница 39: ...nly for the entire RS 485 Bus Generally this point should be chosen on the master device or on its tap and not shared with other devices inverters which could add external noise or disturbance 3 1 4 RS 485 shielding A shielded cable is required to guarantee a high degree of immunity to EMC and lightning events The improvement of EMC immunity can also be done connecting the minus of the DC power su...

Страница 40: ... RS 485 topology Due to signal reflection issues topology is not free but only certain configurations are allowed The only configuration which guarantees sufficient reliability is the daisy chain The maximum length of a derivation is 1 metre ...

Страница 41: ...ipment UNAUTHORIZED PEOPLE MUST NOT TOUCH The product contains electrical components constantly under voltage Only skilled personnel correctly trained to operate on circuits constantly under voltage are allowed to open the cover of the device DO NOT USE WATER TO PUT OUT FIRE Water jets or jets of other liquids must not come in contact with the electric panel INSTALL AVOIDING DIRECT EXPOSURE TO SUN...

Страница 42: ...amage to the equipment and injury to operators Use cable lugs for any wiring cables DANGER RISK OF DAMAGE AND INJURY AS A RESULT OF INCORRECT GROUNDING Carefully check grounding The user must provide a grounding system in compliance with the regulations in force according to the electrical installation in use DANGER FIRE HAZARD IN THE PRESENCE OF INFLAMMABLE FUMES There is a fire or explosion haza...

Отзывы: