51
Code
Variable
Conversion Statement
Comments
X
Max IL1
during ramp-
down
- Convert LSB13 to binary, left arithmetic shift by 2
and store the result in variable
𝑥
- Convert MSB13 to binary, right arithmetic shift by 6
and store the result in variable
𝑦
- Convert (
𝑥
+
𝑦
) to decimal and store the result in
variable
𝑧
- Conversion result =
𝑧
N/A
Y
Max IL2
during ramp-
down
- Convert MSB13 to binary, bitwise-AND by
0b00111111, left arithmetic shift by 4 and store the
result in variable
𝑥
- Convert LSB14 to binary, right arithmetic shift by 4
and store the result in variable
𝑦
- Convert (
𝑥
+
𝑦
) to decimal and store the result in
variable
𝑧
- Conversion result =
𝑧
N/A
Z
Max IL3
during ramp-
down
- Convert LSB14 to binary, bitwise-AND by
0b00001111, left arithmetic shift by 6 and store the
result in variable
𝑥
- Convert MSB14 to binary, right arithmetic shift by 2
and store the result in variable
𝑦
- Convert (
𝑥
+
𝑦
) to decimal and store the result in
variable
𝑧
- Conversion result =
𝑧
N/A
Code
AA
AB
Format
LSB15
MSB15
Bits
224 225 226 227 228 229 230 231 232 233 234
235 236 237 238
239
Code
Variable
Conversion Statement
Comments
AA
NTC
Temperature
(max)
- Convert LSB15 to decimal and store the
result in variable
𝑥
- Conversion result =
𝑥
Scaling Factor: +50
AB
Junction
Temperature
- Convert MSB15 to decimal and store the
result in variable
𝑥
- Conversion result =
𝑥
Scaling Factor: +50
28
b
yt
es
29
b
yt
es
30
b
yt
es