43
LSB11
00h
MSB11
00h
LSB12
75h
MSB12
0Ch
LSB13
00h
MSB13
80h
LSB14
20h
MSB14
08h
LSB15
48h
MSB15
49h
LSB16
00h
MSB16
20h
* Two hexadecimal digits represent one byte.
Step 4: By using the conversion formula convert each byte to display information of the respective start.
Code Variable
Description
A
Start number
The start number to which the data belongs
B
System voltage & phase sequence
The system voltage and phase sequence during power-up
C
Ramp-up time
Ramp-up time setting
D
Initial firing angle
The initial firing angle at which the SCR turned on
E
Current balancing setting
Variable related to current balancing algorithm
F
Spare
Reserved
G
Alarm reset mode
Auto or manual alarm reset setting
H
Phase sequence alarm mode
Phase sequence alarm setting
I
Motor overload alarm mode
Motor overload alarm setting
J
Current Limit Setpoint
The value of current limit
K
Ramp-down time
Ramp-down time setting
L
FLC setting
Full load current setting
M
Max IL1 during ramp-up
The maximum current measured on phase 1 during ramp-up
N
Max IL2 during ramp-up
The maximum current measured on phase 2 during ramp-up
O
Max IL3 during ramp-up
The maximum current measured on phase 3 during ramp-up
P
HP mode
Indicates if start was done in HP
Q
Time to reach full speed
The time duration that the motor took to reach full speed
R
Time to reach continuous current
The time duration that the device took to reach continuous
current
S
Max IL1 during bypass
The maximum current measured on phase 1 during bypass
T
Max IL2 during bypass
The maximum current measured on phase 2 during bypass
U
Max IL3 during bypass
The maximum current measured on phase 3 during bypass
V
Torque on leaving bypass
The measured torque when the soft starter entered into
ramp-down mode
W
Ramp-down duration
The time duration that the soft starter took to stop the motor
X
Max IL1 during ramp-down
The maximum current measured on phase 1 during ramp-down
Y
Max IL2 during ramp-down
The maximum current measured on phase 2 during ramp-down
Z
Max IL3 during ramp-down
The maximum current measured on phase 3 during ramp-down
AA
NTC temperature (max)
The maximum internal temperature measured by the
temperature sensor
AB
Junction temperature
The maximum junction temperature
AC
Estimated motor temperature
The temperature of the motor based on measurement of the
current consumed
AD
Soft starter status after stopping
The soft starter status after ramp-down