Electromagnetic compatibility (EMC) - immunity
Electrostatic discharge (ESD)
EN/IEC 61000-4-2
8 kV air discharge, 4 kV contact (PC2)
Radiated radio frequency
EN/IEC 61000-4-3
3 V/m, from 80 MHz to 1 GHz (PC1)
3 V/m, from 2 to 2.7 GHz (PC1)
Electrical Fast Transient (Burst)
EN/IEC 61000-4-4
Output: 2 kV, 5 kHz (PC2)
Input: 1 kV, 5 kHz (PC2)
Conducted Radio Frequency
EN/IEC 61000-4-6
3 V/m, from 0.15 to 80 MHz (PC1)
Electrical Surge
EN/IEC 61000-4-5
Output, line to line: 1 kV (PC2)
Output, line to earth: 2 kV (PC2)
Input, line to line: 0.5 kV (PC2)
Input, line to earth: 1 kV (PC2)
Voltage dips and interruptions
EN/IEC 61000-4-11
Electromagnetic compatibility (EMC) - emissions
Radio interference field
emissions (conducted)
CISPR 11, EN/IEC 55011
Class B
1
Harmonics
IEC/EN 61000-3-2
1
IEC/EN 61000-3-12
1
Disturbance power
CISPR 14, IEC/EN 55014-1
1
Flicker
IEC/EN 61000-3-11
1
(load conditions apply)
Compatibility and conformity
Conformance
IEC/EN 60947-4-2, UL60947-4-2
Approvals
1. Applicable when current limit is ≤ 45 A
rms
Note:
• Performance Criteria 1 (PC1): No degradation of performance or loss of function is allowed when the product is operated
as intended.
• Performance Criteria 2 (PC2): During the test, degradation of performance or partial loss of function is allowed. However
when the test is complete the product should return operating as intended by itself.
• Performance Criteria 3 (PC3): Temporary loss of function is allowed, provided the function can be restored by manual
operation of the controls.