1. Introduction

This manual is a reference guide for Carlo Gavazzi loop detector LDP1 and LDP2. It describes the product 

specifications as well as how to install, set up and use the product for its intended use.

1.2 Validity of documentation

This manual is valid only for LDP1 and LDP2 Loop detector and until any newer documentation is published.

This instruction manual describes the functions, operations and installation of the product for its intended 

use.

1.6 Other documents

It is possible to find the datasheet, manuals, brochures and electrical drawings on the Internet at 

 

http://gavazziautomation.com

1.5 Safety precautions

This loop detector must not be used in applications where personal safety depends on the function of the loop 

detector (The loop detector is not designed according to the EU Machinery Directive).

Installation and use must be carried out by trained technical personnel with basic electrical installation knowledge.

The installer is responsible for correct installation according to local safety regulations and must ensure that a 

defective loop detector will not result in any hazard to people or equipment. If the loop detector is defective, it 

must be replaced and secured against unauthorized use.

1.3 Who should use this documentation

This manual contains important information regarding installation and must be read and completely 

understood by specialized personnel dealing with these kinds of devices.

We highly recommend that you read the manual carefully before installing the loop detector. Please save 

the manual for future use. The installation manual is intended solely for qualified technical personnel.

1.4 Use of the product

Loop detector is primarily used to detect vehicles such as cars, trucks, buses and others.

A loop on the ground is required for the loop detector to detect any vehicles above the loop. The device 

works on the same principle of an inductive sensor; utilizing the phenomenon of eddy current. When a 

metal target/vehicle approaches on top of the loop, the magnetic field generated by the loop interacts with 

the target and make the loop detector to change its status. 

Loop detector can be used in carpark barriers, bollards, gates, toll gantries and many other door access 

applications.

1.1 Description

Carlo Gavazzi loop detector are devices designed and manufactured in accordance with IEC international 

standards and are subject to the Low Voltage (2014/35/EU) and Electromagnetic Compatibility (2014/30/

EU) EC directives.

All rights to this document are reserved by Carlo Gavazzi Industri: copies may be made for internal use 

only.

Please do not hesitate informing us to make any suggestions for improving this document.

Содержание LDP1

Страница 1: ...e and Dual Loops Plug In Carlo Gavazzi Industri Over Hadstenvej 40 8340 Hadsten Denmark Instruction manual Manuel d instructions Manuale d istruzione Betriebsanleitung Manual de instrucciones Brugerve...

Страница 2: ...ENGLISH page 3 DEUTSCH seite 32 FRAN AIS page 62 ESPA OL p gina 92 ITALIANO pagina 122 DANSK side 152 182...

Страница 3: ...5 2 Teach from IO Link Master 17 2 6 Sensor Specific adjustable parameters 20 2 6 1 Selection of local or remote adjustment 20 2 6 2 Process data and variables 20 2 6 3 Sensor application setting 20 2...

Страница 4: ...secured against unauthorized use 1 3 Who should use this documentation This manual contains important information regarding installation and must be read and completely understood by specialized perso...

Страница 5: ...andard Input Output SP Setpoints IODD I O Device Description IEC International Electrotechnical Commission NO Normally Open contact NC Normally Closed contact NPN Pull load to ground PNP Pull load to...

Страница 6: ...selectable operation as pulse or presence switching Multicolor power fault LED indication for easy setup and intuitive diagnostic Individual loop state multicolor LED to indicate different loop status...

Страница 7: ...ifetime 100 000 operations 5A load Protection Reverse polarity and transients Rated operational voltage UB 24 240 VAC VDC LDP1 Power consumption 24 VAC VDC 2 W 3 5 VA 115 VAC VDC 2 W 6 VA 240 VAC VDC...

Страница 8: ...upply 2 Supply 3 Relay 1 N O 4 Relay 1 COM 5 Relay 2 N O 6 Relay 2 COM 7 Loop 8 Loop 9 Earth 10 Relay 2 N C 11 Relay 1 N C Earth pin must be connected to earth Do not wipe grease off pins Dual loop LD...

Страница 9: ...Industri 9 EN 4 Structure Loop 2 LED Relay 2 LED Power Fault LED Reset button Loop LED Relay 1 LED Relay 2 LED Dip switch Potentiometer LDP1 Single Loop Power Fault LED Reset button Potentiometer loo...

Страница 10: ...gnal indication Channel crosstalk ASB ON indication 5 LED indications In general LDP loop detectors have 3 categories of LED indications namely Power Fault indicator LED Loop state LED and Relay state...

Страница 11: ...t is turned ON and everything is working well 5 2 Loop state LED Explanation 1 Green LED steady Loop inductance is within limit and working well 2 Yellow LED steady Loop inductance is too high more th...

Страница 12: ...noise levels on all channels and automatically select the channel with the least noise This will be done once every time the loop detector is powered up Set DIP SWITCH 1 to ON for manual selection Us...

Страница 13: ...er such as in private areas private apartments etc Note The fail safe and fail secure mentioned above is only referring to the power loss to the loop detector and not referring to the power loss of th...

Страница 14: ...omatic channel selection Manual channel selection 2 Channel selection DIP switch 2 and 3 are not used in automatic channel selection 1 2 3 4 3 General settings 4 Turn on delay Delay OFF Delay 2 0 sec...

Страница 15: ...7 or switch 9 the relay output can set to be activated when vehicle enters the loop or only when the vehicle exits the loop If presence mode is selected instead in switch 7 or switch 9 switch 8 and s...

Страница 16: ...fic II Typically the loop should be around 2m L x 1m D However this could be different depending on the actual road size III The loop should reach maximum to within 300mm on each side to the edge of t...

Страница 17: ...from that loop corner to the loop detector III Minimum 20 twists per every meter IV Maximum feeder wire length is 20 meters length from loop to loop detector V Feeder wire should not be in parallel w...

Страница 18: ...and Dual Loop Detector 2018 CARLO GAVAZZI Industri 18 EN 7 1 3 Adjacent Loops I Minimum distance of 2m shall be observed between 2 adjacent loops II If dual loop LDP2 is used the loops can be install...

Страница 19: ...ometry groove must be cut into the ground to install the loop This can be done by using a concrete cutting disc saw or similar device Clean the groove to make sure it is free of debris and free from m...

Страница 20: ...l II Make sure that there is no object vehicle on top of the loop III Turn on the power switch to the loop detector IV The loop detector will automatically calibrate the loop inductance to optimal lev...

Отзывы: