Rev.00 - 09.2018 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 |
CARLO GAVAZZI Industri
10
EN
Loop state LED
LED colour
LED constant
LED Flashing (3 Hz)
Inductance OK
-
Inductance too high
Inductance too low
Loop is open circuit
Loop is short circuit
Relay state LED
LED colour
Mode
Relay
deactivated
Relay activated
Presence mode
OFF
ON
Pulse mode, 0.1 s
OFF
Flashing 0.5 s
Pulse mode, 0.5 s
OFF
Flashing 1.0 s
Power / fault indicator
LED colour
LED constant
LED Flashing (1 Hz)
All OK (ASB OFF)
DIP switch changed, but
product not reset
Low signal indication
-
Channel crosstalk
-
ASB ON indication
-
5. LED indications
In general, LDP loop detectors have 3 categories of LED indications; namely Power/Fault indicator
LED, Loop state LED and Relay state LED:
Single loop (LDP1)
Loop state LED
LED colour
LED constant
LED Flashing (3 Hz)
Inductance OK
-
Inductance too high
Inductance too low
Loop is open circuit
Loop is short circuit
Relay state LED
LED colour
Mode
Relay
deactivated
Relay activated
Presence mode
OFF
ON
Pulse mode, 0.1 s
OFF
Flashing 0.5 s
Pulse mode, 0.5 s
OFF
Flashing 1.0 s
Power / fault indicator
LED colour
LED constant
LED Flashing (1 Hz)
All OK (ASB OFF)
DIP switch changed, but
product not reset
Low signal indication
-
Channel crosstalk
-
ASB ON indication
-
Dual loop (LDP2)