Rev.00 - 09.2018 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 |
CARLO GAVAZZI Industri
14
EN
DIP Switch settings for Dual Loop (LDP2)
12
3
4
56
78
91
01
11
2
ON
ON
Bit 1 setting
Bit 2 setting
Output Presence Time
0
0
Infinity
0
1
1 hour
1
0
10 minutes
1
1
1 minute
In infinite, the relay will continue to be activated as long as the vehicle is still on the loop.
Frequency settings
1
Selection
mode
Automatic channel selection
Manual channel selection
2
Channel
selection
DIP switch 2 and 3 are not used in
automatic channel selection
1
2
3
4
3
General settings
4
Turn-on delay
Delay OFF
Delay 2.0 sec
5
ASB
ASB OFF
ASB ON
6
Failure mode
Fail safe
Fail secure
Relay 1 settings
7
Output mode
Pulse mode
Presence mode
8
Mode select
Vehicle entry
Vehicle exit
Infinite
1 m
Relay 2 settings
9
Output mode
Pulse mode
Presence mode
10
Mode select
Vehicle entry
Vehicle exit
Infinite
1 m
Relay 1 & 2 settings
11
Pulse
duration
0.1 s
0.5 s
Not used in Presence mode
General settings
12 Direction logic
OFF
ON