Rev.00 - 09.2018 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 |
CARLO GAVAZZI Industri
12
EN
6. Dip Switch
DIP Switch settings for Single Loop (LDP1)
12
3
4
56
78
91
01
11
2
ON
ON
DIP-switch 1 - Selection mode:
The loop detector operates on one out of four channels.
Depending on the noise sources in the vicinity (other loop detectors/frequency converters/starters
etc. i.e. crosstalk) can it be helpful to choose a channel where the loop detector is not disturbed by
the noise. The loop detector will indicate by a white flash which channel the loop detector are using
after power up.
Set DIP SWITCH 1 to OFF for automatically selection During startup will the loop detector
measure the noise levels on all channels and automatically select the channel with the least noise. This
will be done once every time the loop detector is powered up.
Set DIP SWITCH 1 to ON for manual selection Use dip switch 2 and 3 for selecting channel 1
,2 ,3 or 4.
Frequency settings
1
Selection
mode
Automatic channel selection
Manual channel selection
2
Channel
selection
DIP switch 2 and 3 are not used in
automatic channel selection
1
2
3
4
3
General settings
4
Turn-on delay
Delay OFF
Delay 2.0 sec
5
ASB
ASB OFF
ASB ON
6
Failure mode
Fail safe
Fail secure
Relay 1 settings
7
Output mode
Pulse mode
Presence mode
8
Time
0.1 sec pulse
0.5 sec pulse
Infinite
60 min
10 min
1 min
9
Entry / Exit
Vehicle entry
Vehicle exit
Relay 2 settings
10 Output mode
Pulse mode
Presence mode
11
Time
0.1 sec pulse
0.5 sec pulse
Infinite
60 min
10 min
1 min
12
Entry / Exit
Vehicle entry
Vehicle exit