Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 |
CARLO GAVAZZI Industri
28
EN
7.2. IO-Link Device Parameters for LD30 IO-Link
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Vendor Name
16 (0x10)
RO
Carlo Gavazzi
-
StringT
20 Byte
Vendor Text
17 (0x11)
RO
www.gavazziautomation.com
-
StringT
26 Byte
Product Name
18 (0x12)
RO
(Sensor name)
e.g. CA30CAN25BPA2IO
-
StringT
20 Byte
Product ID
19 (0x13)
RO
(EAN code of product)
e.g. 5709870394046
-
StringT
13 Byte
Product Text
20 (0x14)
RO
Photoelectric Sensor
-
StringT
30 Byte
Serial Number
21 (0x15)
RO
(Unique serial number)
e.g. LR24101830834
-
StringT
13 Byte
Hardware Revision
22 (0x16)
RO
(Hardware revision)
e.g. v01.00
-
StringT
6 Byte
Firmware Revision
23 (0x17)
RO
(Software revision)
e.g. v01.00
-
StringT
6 Byte
Application Specific Tag
24 (0x18)
R/W
***
Any string up to 32 characters
StringT
max 32 Byte
Function Tag
25 (0x19)
R/W
***
Any string up to 32 characters
StringT
max 32 Byte
Location Tag
26 (0x1A)
R/W
***
Any string up to 32 characters
StringT
max 32 Byte
Error Count
32 (0x20)
RO
0
0 ... 65 535
IntegerT
16 Bit
Device Status
36 (0x24)
RO
0 = Device is operating properly
0 = Device is operating properly
1 = Maintenance required
2 = Out-of-specification
3 = Functional-Check
4 = Failure
UIntegerT
8 Bit
Detailed Device Status
37 (0x25)
-
-
3 Byte
Temperature fault
-
RO
-
-
OctetStringT
3 Byte
Temperature over-run
-
RO
-
-
OctetStringT
3 Byte
Temperature under-run
-
RO
-
-
OctetStringT
3 Byte
Short-circuit
-
RO
-
-
OctetStringT
3 Byte
Maintenance Required
-
RO
-
-
OctetStringT
3 Byte
Process-DataInput
40 (0x28)
RO
-
-
IntegerT
32 bit
7.2.1.
Device parameters