15
TyrFil Flushless Pump
| Flatproofi ng Technical Manual
3. Open the manifold valve to release the pressure inside the
cylinders and hoses. Close the manifold valve when the
pressure on the cylinders is zero.
4. Remove the manifold head from the handle over a waste
container and allow excess material to drain.
5. Rest the manifold on the ground or breakdown on a table for
easier disassembly and clean-up. Close the pressure gauge
valve and remove the pressure gauge.
6. Remove the whip hose and mixing tube from the manifold
head.
7. Wash the manifold head in solvent. Open ball valve on the
manifold and rinse the gauge port with solvent. Store manifold
head in the solvent when clean.
8. Eject the mixing elements from the mixing tube and wash the
elements in the solvent. Store mixing elements in a safe place
to avoid breakage. Clean mixing tube with a steel brush and
place mixing tube in the solvent container.
9. Wipe off any excess material from the manifold handle with a
clean rag and place on hanger.
10. Thoroughly clean and store tools in their proper place.
11. Clean all mixed material off fl oor and machine.
4
5
7
8
8
Содержание TyrFil
Страница 26: ...NOTES...