Dynacode IP Series
Function Menu
08.16
Operating Manual
63
12.10 I/O Parameters
Switch on the direct print module and the display shows the main
menu.
Press key
to access the function menu.
Press key
as long as you arrive the
I/O Parameters
menu.
Press key
to select the menu.
Indication of signal at which a print order is started
+
= active signal level is 'high' (1)
-
= active signal level is 'low' (0)
x
= signal level is not activated
s
status can be affected by interface
*
The modification of the signal level is only taken into consideration for
the operating modes I/O static, I/O dynamic, I/O static continuous and
I/O dynamic continuous.
Press key
to arrive the next menu item.
Angabe des Signalpegels für Ausgabesignal.
+
= active signal level is 'high' (1)
-
= active signal level is 'low' (0)
s
= status can be affected by interface *
Press key
to arrive the next menu item.
Indication of debounce time of the dispenser input. The setting range
of the debounce time is between 0 and 100 ms.
In case the start signal is not clear then you can debounce the input
by means of this menu item.
Press key
to arrive the next menu item.
Indication in time per second of the delay for the start signal.
Value range: 0.00 to 9.99.
Press key
to arrive the next menu item.
On:
If a print order is active but the direct print module is not ready to
process the order (e.g. if it is already in 'printing' mode), then an error
message appears.
Off:
No error message appears.
Press key
to arrive the next menu item.
Selection of the available configurations
Std_Direct
(factory setting) or
StdFileSelDirect
.
The corresponding assignment is indicated on the following page.
*
in combination with Netstar PLUS
IN signal level
OUT signal level
Debounce
Start signal delay
Not ready: error
I/O Profile