Ribbon Save / Foil Saving
Dynacode IP Serie
116
Operating Manual
08.16
18.2 Standard Ribbon Save (Continuous Mode)
Switch on the control unit and the display shows the main menu.
Press key
to access the function menu.
Press key
as long as you arrive the
Ribbon save
menu.
Press key
to select the menu.
Press key
and
to select the ribbon save mode
Standard
.
Press key
to arrive the first menu item.
TR Correction
0 mm
= It is always so far retracted that an optimal ribbon save is
reached (no loss of transfer ribbon). This is rather rarely realised, as
the ribbon position can deviate because of inaccuracies at speed
measurement (encoder).
Default: -1 mm
−
xx mm
= The feedback can be made smaller. It causes loss of
transfer ribbon but the number of cycles is increased. If the value is
increased to the complete backfeed length then the direct print
module sets automatically the max. value and no more backfeed is
accomplished.
+xx mm
= The feedback can be made larger. This causes that it is
printed onto the transfer ribbon in the previous printout.
W W
W W
W W
W W
Ribbon save mode
Transfer ribbon
correction
Example