9.3 Increasing the clamping force for ribbon roll
NOTICE!
The use of high-quality transfer ribbon with a cardboard core is
recommended. A sample ribbon roll is included in the scope of
delivery. The clamping force of transfer ribbon roll placed on
the rewinding/unwinding unit is designed for this quality.
A
B
C
Figure 26
If other transfer ribbons are used, it can occur that the clamping force
of the spring plates (B) is not sufficient, in order to position the rolls
surely and to protect it against rotating.
When using transfer ribbons with plastic cores a safe positioning of
the roles cannot be ensured.
CAUTION!
Slippage of transfer ribbon roll placed on the rewinding/
unwind unit or the empty cardboard core leads to
malfunctions.
When using transfer ribbon rolls with plastic cores the
groove must be shimmed.
Remove screws (A) and spring plates (B).
Insert the shims (C) into the groove. The shims are available from
us (item no. 52.57.110).
Fasten again spring plates (B) and shims (C) with screws (A).
Insert transfer ribbon roll and empty cardboard core on the
rewinding/unwinding unit.
Check firm position!