Compa II
Options
03.20
Operating manual
75
Press the key
to move to the next parameter.
This menu serves for the applicator setup as well as for error tracing.
Input signals of the applicator can be monitored and output signals
can be set or reset separately. Press the key
and
to select the
corresponding output for set/reset the output signals. Press the keys
and
to set/reset the corresponding output.
Input signals
I
1
=
Pre-dispense key
1 = key pressed
0 = key not pressed
I
2
=
Final position up
1 = pad in final position up
0 = pad not in final position up
I
3
=
Final position down
1 = pad in final position down
0 = pad not in final position down
I
4
=
Compressed air
1 = compressed air available
0 = no compressed air available
I
5
=
Vacuum
1 = vacuum at pad available
0 = no vacuum at pad available
I
6
=
Final position right
1 = pad in final position right
0 = pad not in final position right
I
7
=
Final position left
1 = pad in final position left
0 = pad not in final position left
Output signal
O
1
=
Move pad downwards
1 = On / 0 = Off
O
2
=
Move pad upwards
1 = On / 0 = Off
O
3
=
Transverse right
1 = On / 0 = Off
O
4
=
Transverse left
1 = On / 0 = Off
O
5
=
Blowing air
1 = On / 0 = Off
O
6
=
SUpporting air
1 = On / 0 = Off
O
7
=
Vacuum
1 = On / 0 = Off
Input/Output
Содержание COMPA II
Страница 1: ...COMPA II Operating Manual ...
Страница 10: ...Introduction Compa II 10 Operating manual 03 20 ...
Страница 16: ...Safety Notes Compa II 16 Operating manual 03 20 ...
Страница 26: ...Technical Data Compa II 26 Operating manual 03 20 ...
Страница 30: ...Installation Compa II 30 Operating manual 03 20 ...
Страница 42: ...Load Media Compa II 42 Operating manual 03 20 ...
Страница 64: ...Function menu Compa II 64 Operating manual 03 20 ...
Страница 104: ...Error Correction Compa II 104 Operating manual 03 20 ...
Страница 112: ...Environmentally Friendly Disposal Compa II 110 Operating manual 03 20 ...