Options
Compa II
72
Operating manual
03.20
Press the key
to move to the next parameter.
The vacuum is connected not immediately with print start, but only if
the label were put forward a certain time. This delay causes that the
label runs more easily under the pad as it is not sucked and in this
way braked.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 0 ms
Press the key
to move to the next parameter.
The supporting air from the blow tube is not immediately switched on
at print start but only if the label has covered a distance.
This delay helps to prevent a turning or swinging at the front of the
label and consequently avoids faults when the label is being picked up
from printer.
Value range: 0
… 2500 ms
Step size: 0 ms
Default: 0 ms
Press the key
to move to the next parameter.
Delayed to the process of the label being picked up, the supporting air
is switched off.
In many cases, after being picked up by the pad the label edge may
still stick on the liner. This may affect the accuracy of the label
positioning or even cause faults in the labelling. Therefore, switching
off the air blow delayed can be useful to separate the label from liner
and neatly place the label on the surface of pad.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 500 ms
Press the key
to move to the next parameter.
With activated compressed air control, with help from a compressed
air sensor it is checked at each labelling cycle if the compressed air
fits with the valve block. If no compressed air is presented, the
labelling cycle is stopped and the error message 'compressed air' is
displayed.
If the parameter 'pressure control' is set to Off, the error treatment as
described above will not be effected. This can be especially helpful for
the initial operation of the labelling system.
For standard operation, set the parameter to On.
Press the key
to move to the next parameter.
The label transfer from printer to applicator is controlled by a vacuum
sensor. If the transfer of label fails, the sucking holes on the pad will
not be covered by the label and therefore no vacuum can originate on
the pad. Afterwards an error message appears and the label strip will
be fed back.
If the parameter 'vacuum control' is set to Off, the error treatment as
described above will not be effected. This can be especially helpful
during adjustments, because the immediate backfeed will be
cancelled and therefore it is easier to check the reasons for the faulty
transfer.
For standard operation, set the parameter to On.
Vacuum delay
Support delay On
Support delay Off
Pressure control
Vacuum control
Содержание COMPA II
Страница 1: ...COMPA II Operating Manual ...
Страница 10: ...Introduction Compa II 10 Operating manual 03 20 ...
Страница 16: ...Safety Notes Compa II 16 Operating manual 03 20 ...
Страница 26: ...Technical Data Compa II 26 Operating manual 03 20 ...
Страница 30: ...Installation Compa II 30 Operating manual 03 20 ...
Страница 42: ...Load Media Compa II 42 Operating manual 03 20 ...
Страница 64: ...Function menu Compa II 64 Operating manual 03 20 ...
Страница 104: ...Error Correction Compa II 104 Operating manual 03 20 ...
Страница 112: ...Environmentally Friendly Disposal Compa II 110 Operating manual 03 20 ...