MANUAL OVERRIDE
In the event of a malfunction in the electrical system the electric valve can still be operated by activating
the manual control fitted for that purpose.
MAKE SURE THAT THE DOORS ARE OPEN!
When using this manual override you must always ensure that it switched back to the original,
NON-ACTIVATED condition after use.
Activation of the manual override: ON
Remove the yellow security clip and turn in (clockwise) the red button on top of the on/off GS02 solenoid
till the stop.
Deactivation of the manual override: ON
Turn out (counter clockwise) the red button on top of the GS02 solenoid until the click and place back the
yellow security clip. The system switch “off”.
Activation of the manual override control loading (floor will only be able to load):
Screw the black cap off (pay attention to the O ring).
Turn out (counter clockwise) the screw under the cap of the load / unload G02 till the stop.
Deactivation of the manual override loading:
Turn in (clockwise) the screw under the cap of the load / unload G02 till the stop.
Screw the black cap back on (pay attention to mounting the O ring).
Load/unload solenoid/coil
Not activated
Function: Unloading
Load/unload solenoid/coil
Activated
Function: Loading
On /off solenoid/coil
Manually activated
On / off solenoid/coil
Not activated