CF8 SWITCH (MAIN CONTROL)
The standard supplied remote control CF8, with
10 meter [30’] of cable, is used for the day-to-day control
of the system. The CF8 switch is fitted with the following functions:
The CF8 switch has a plug connector, which can be inserted into the connector of the CF7 switch and
screwed tight.
To disconnect this, the duct must be unscrewed, after which the plug can be pulled out. Normally, this
plug should always be connected to the connector.
CF7 SWITCH
The CF7 switch is the permanent switch which is mounted in the control box and has 3 switch positions
with the following functions:
In the interest of safety this switch is fitted with an automatic spring-back for positions I and II, so that it
always returns to the central “0” position. This is necessary to prevent conflict situations arising when
using the CF8 remote control. Mounted below the CF7 switch, is a connector to which the CF8 switch or
the RX RECEIVER can be connected without the need for any adjustments. Normally, the CF7 switch
should only be used if the CF8 switch is defective. If, after the initial assembly, the switch does not work
it is probably because the connections for the + (brown) and the
– (blue) have been swapped around.
The supply cable contains a blocking diode which prevents damages arising from the + and - from being
connected in reverse.
A 2 Amp fuse has been mounted in the CF7 switch. Never mount a fuse over 3A, this can cause damage
to the electrical installation
When turned left or right, it will start the floor and when
released it will automatically return to the 0 position
Red button
Push in for an immediate STOP.
Deactivate by turning.
Loading
.
Unloading
Unloading
Turn right, it will start the
floor and when released
it stays locked.
Rotary switch
Red button
Push in for an
immediate STOP.
Deactivate by turning.
Loading
Turn left, it will start the
floor and when released
it will automatically
return to the stop position