11
ENG
“EVD mini” +0300036EN - rel. 1.2 - 23.04.2018
Installation environment
Important:
avoid installing the drivers in environments with the
following characteristics:
•
relative humidity greater than 90% or with condensation;
•
strong vibrations or knocks;
•
exposure to continuous water sprays;
•
exposure to aggressive and polluting atmospheres (e.g.: sulphur
and ammonia fumes, saline mist, smoke) to avoid corrosion and/or
oxidation;
•
strong magnetic and/or radio frequency interference (therefore avoid
installing the devices near transmitting antennae);
•
exposure of the driver to direct sunlight and to the elements in general.
Important:
the following warnings must be observed when
connecting the driver:
•
if the driver is used in a way that is not specified in this user manual,
protection cannot be guaranteed;
•
incorrect power connections may seriously damage the driver;
•
use cable ends suitable for the corresponding terminals. Loosen each
screw and insert the cable ends, then tighten the screws and gently
tug the cables to check they are sufficiently tight;
•
separate as much as possible (at least 3 cm) the probe and digital
input cables from power cables to avoid possible electromagnetic
disturbance. Never run power cables (including the electrical panel
cables) and probe signal cables in the same conduits;
•
do not run probe signal cables in the immediate vicinity of power
devices (contactors, circuit breakers, etc.). Reduce the path of probe
cables as much as possible, and avoid spiral paths that enclose power
devices;
•
avoid powering the controller directly from the main power supply in
the panel if this supplies different devices, such as contactors, solenoid
valves, etc., which will require a separate transformer;
•
*EVD mini/ice is a controller to be incorporated into the final
equipment; it must not be wall-mounted;
•
* DIN VDE 0100: protective separation must be guaranteed between
the SELV circuits (Safety Extra Low Voltage) and the other circuits. The
requirements of DIN VDE 0100 must be complied with. To prevent
disruption of the protective separation (between the SELV circuits and
the other circuits) ensure additional fastening near the terminations.
This additional fastening must secure the insulation and not the wires.
2.5 Copy parameters with programming key
Note:
•
The parameters must only be copied when the driver is NOT powered;
•
also see the programming key technical leaflet, P/N +050003930.
Procedure:
A.
Open the cover on the key using a screwdriver;
B.
Set the microswitches based on the operation :
- UPLOAD: microswitches 2 = OFF,
- DOWNLOAD: microswitches 1= OFF,
microswitches 2 = ON
See leaflet +050003930
A
B
Fig. 2.k
EV
D
mini (24 V)
Important:
do not use a screwdriver to remove the cover on the
display, to avoid damaging the board.
To remove the cover of the display:
1
Apply a pressure rightward on the left side of the cover.
2
Raise up the right side to extract it.
3
Plug the key into the provided connector, then perform the desired
operation (UPLOAD/DOWNLOAD).
GAS Type
Mode
Super Heat
press
L
press
GAS Type
Mode
Super Heat
1
2
3
Fig. 2.l
EV
D
mini (230 V)
To remove the cover of the display:
1
Press with a screwdriver as shown in the figure, to remove the cover.
2
Lift the cover and remove it.
3
Plug the key into the provided connector, then perform the
desired operation (UPLOAD/DOWNLOAD).
GAS Type
Mode
Super Heat
L
GAS Type
Mode
Super Heat
press
press
1
2
3
Fig. 2.m