Carefree of Colorado
Wind Smart
Auto-Retract System
13
052987-002R5
D05 A
WNING
D
OES
N
OT
A
UTO
-R
ETRACT
D
URING
W
INDY
C
ONDITIONS
NOTE: The mode switch must be set to “Wind Smart ON”
YES
Function works using the switch; go
to test B
A
Confirm that the retract function works using the P
ATIO
switch
NO
Function does not work with switch;
go to procedure D01 on page 12
B
Test Anemometer
YES
Go to step B2
1 Do the anemometer cups spin freely?
NO
Anemometer defective - replace
YES
Plug the connector into the control
box;
Go to “Testing The Control Box”
2 Test signal from anemometer:
2.1 Remove anemometer connector from control box;
2.2 Place continuity tester between pins of connector;
2.3 Have a helper slowly turn the anemometer:
Does the circuit open and close? It should open
and close once for every revolution.
NO The circuit stays open or stays
closed; go to step B3
YES
Continuity OK; replace anemometer
3 Test the wire continuity between the connector and the
anemometer.
NO
Repair or Replace wires as required
D06 T
ESTING
A
S
WITCH AND
H
ARNESS
Disconnect the switch harness connectors from the control box and remove the plate and switches from the
mounting surface.
YES
Switch mounted OK; go to test B
A
Confirm Switch is mounted in correct position and correctly
oriented. Refer to Figure 5 on page 8. The lens or lens caps
should be on the bottom of the switch as indicated by the
shaded area.
NO
Carefully remove the switch, rotate
180 and reinstall in panel.
Reconnect harnesses and retest
YES
Switch wired OK; go to test C
B
Confirm switch is wired correctly. Use the schematic and
confirm the wires from the switch to the connector are
correctly placed.
NO
Rewire the switch according to the
schematic on page 16
C
Test the Switch Function (this test requires a continuity tester)
•
Do not remove the wires from the back of the switch. From the numbered terminal of the switch, trace the wire to
the connector; place the tester leads on the connector pins. The pins are not marked on the connector.
•
Steps 1 through 5 are for the Patio and Wind Speed Switches. Refer to step 6 for the Mode Switch.
YES
Circuits are open, go to step 2.
1 Using a continuity tester, place one lead on common (Pin
3 – Patio; pin 5 – Wind Speed). Place the second lead on
pin 1. Put the switch in the center position and measure
the continuity. Move the second lead to pin 7, measure
the continuity.
Circuit should be open
NO
Circuit(s) are closed (continuity
exists); switch assy is defective -
replace
YES
Circuit closed; go to step 3
2 Place the second lead on pin 1. Press the switch down
(“Extend” for patio, “Lo” for sensitivity). Is circuit closed?
NO
Circuit open; switch defective-replace
YES
Circuit open; go to step 4
3 Leave the leads in position of step 2. Press the switch up
(“Retract” for patio, “Hi” for sensitivity). Is the circuit open?
NO
Circuit closed, switch defective-replace
YES
Circuit open; go to step 5
4 Move the second lead to pin 7. Press the switch down
(“Extend” for patio, “Lo” for sensitivity). Is the circuit open?
NO
Circuit closed, switch defective-replace
YES
Circuit closed; go to step 6
5 Leave the leads in position of step 4. Press the switch up
(“Retract” for patio, “Hi” for sensitivity). Is the circuit closed?
NO
Circuit open; switch defective-replace
YES
Switch tests OK, return to diagnostic
6
For Mode Switch only
– Follow steps 1 through 5 using
pins 5, 2 and 8 respectively
NO
Test failed; switch defective
1
7
5
3
2
8
6
4
9
10
Mode
1
7
3
Patio
WS009a
Wind Speed
1
7
5
Table of Contents