6. Specifications
Cardinal Health™ SVED®
Dimensions .................................................................................................................................19.4 x 7.2 x 18cm (7.6 x 8 x 7.1 in.)
Weight ........................................................................................................................................................................ 0.9kg (2.0 lb.)
Therapy Settings .............................................................................................................................................-70, -120, -150mmHg
IEC Classification
• Medical Equipment
• Equipment not suitable for use in presence of flammable
anesthetic mixture with air, oxygen, or nitrous oxide.
• Continuous Operation
• Type BF Applied Part
• Class II Internally Powered Equipment
• IP22 -
Drip proof from rain falling at 15-degree angle
Battery
Duration (Fully Charged) .............................................................................................................................................up to 18 hours
Electrical
External Power Supply Input .....................................................................................................100-240VAC, 50-60Hz, 0.8Amp Max
External Power Supply Output .....................................................................................................................................15VDC, 2Amp
Patient & Enclosure Leakage Current ....................................................................................................................< 100Micro amps
SVED® Storage Conditions
Note:
Storage and Operation Conditions do not apply to the Additional Parts Identified within Section 7
Temperature Range ................................................................................................................................-12°C (10°F) to 30°C (90°F)
Relative Humidity Range ......................................................................................................................... 65 +/-20% (45% to 80%)
Atmospheric Pressure Range...................................................................................................................................50kPa to 110kPa
Time to Warm from -12°C to 20°C Before Use ............................................................................................................... 120 minutes
Time to Cool from 43°C to 20°C Before Use .................................................................................................................... 120 minutes
SVED® Operating Conditions
Temperature Range .................................................................................................................................... 4°C (40°F) to 32°C (90°F)
Relative Humidity Range ......................................................................................................................... 65 +/-20% (45% to 85%)
Atmospheric Pressure Range...................................................................................................................................50kPa to 110kPa
Service Life ............................................................................................................................................................................. 3 years
CAUTION:
Federal law restricts this device to sale by, or on the order of, a physician.