Safety and Warnings

Note to healthcare personnel providing training to lay users or lay caregivers (lay responsible 

organizations):

 Be sure to include all of the warnings below when providing training to lay operators, especially 

in a home care environment. Lay users and caregivers should contact Customer Support if there is a change in 
the performance of the Catalyst™. Additionally, lay users and caregivers should be instructed on proper cleaning 
procedures to avoid hazards such as electric shock. Lay users and caregivers should also be trained on inappropriate 
environments for use (e.g. bathtub). For guidance on training, please contact Customer Support.

WARNING:

 Strangulation hazard. Do not leave A.C. Power Adapter cord, tubing, or other choking hazards where 

infants or young children can become caught. If these objects get wrapped around the neck, strangulation and death 
can occur.

WARNING: 

The Catalyst™ contains small parts, which could become detached and pose a choking hazard. Some of 

these components could be inhaled or swallowed by a small child, toddler or infant, which could result in suffocation 
or death. Keep all parts of the Catalyst™ out of reach of small children.

WARNING:

 Do not modify this equipment without authorization from the manufacturer. Modification of this system 

could result in physical hazards, including delayed therapy, electrocution and fire. These hazards could result in injury 
or death.

WARNING:

 Use only the Cardinal Health™ NPWT Occlusion Detection Dressing or Kendall™ NPWT Incision 

Management Dressing and accessories listed in this manual. Use of other dressings and accessories can create 
hazardous situations, including improper therapy or delayed therapy. This could result in improper healing, damage to 
the wound area and infection.

CAUTION:

 Use the Catalyst™ only as described in this User Manual. Do not interconnect the Catalyst™ with other 

devices not included in this user manual. Failure to comply could result in improper therapy and could result in damage 
to the Catalyst™.

CAUTION: 

This system is not intended to be used in MRI environments or in the presence of strong magnetic fields. Do 

not use the CATALYST™ in any areas with strong magnetic fields. The system contains metal components which could 
cause unintended movement. This unintended movement could cause clinician or patient harm due to falling objects 
or collisions.

CAUTION: 

If you are in an environment with pet hair, please use caution when adhering the wound dressing to the 

wound site. Pet hair could contaminate the wound site and prevent adhesion of the wound dressing. This could result 
in possible infection of the wound or reduced effectiveness of the system.

CAUTION:

 The Catalyst™ system can be used outdoors for short periods of time (not more than 24 hours). Shelter from 

the rain.

Содержание CATALYST NPWT

Страница 1: ...1 Cardinal Health Negative Pressure Wound Therapy CATALYST Patient User Manual...

Страница 2: ...leak with your dressing What to do if you notice bleeding from the wound What to do if you must take your dressing off What activities you can do while using the CATALYST Who to call if you need help...

Страница 3: ...stem could result in physical hazards including delayed therapy electrocution and fire These hazards could result in injury or death WARNING Use only the Cardinal Health NPWT Occlusion Detection Dress...

Страница 4: ...ATALYST 7 2 2 Charging the Battery 8 2 3 Changing the Canister 10 2 4 Disconnecting from the CATALYST 12 3 Operating Instructions 13 3 1 On Off 13 3 2Troubleshooting 14 4 Care Cleaning 18 4 1 Disposal...

Страница 5: ...h NPWT Occlusion Detection Dressing or Kendall NPWT Incision Management Dressing over exposed blood vessels or organs The Cardinal Health NPWT Occlusion Detection Dressings and Kendall NPWT Incision M...

Страница 6: ...erash maybeaddedsignsofmoreseriouscomplicationsofinfection Extracareandattentionshouldbe givenifthereareanysignsofpossibleinfectionorrelatedcomplications Infectioncanbeserious Withorwithoutthe CATALYS...

Страница 7: ...Negative PressureWoundTherapy Incision Management Dressing Kit is a wound dressing kit to be used with Cardinal Health Negative PressureWoundTherapy NPWT CATALYST ALLY and ALLYTO GO systems K171499 Th...

Страница 8: ...2 Figure 2 3 When the CATALYST is connected to an outlet the green light next to the Plugged In symbol comes on Figure 3 If the battery is charging the yellow light next to the Battery Charging symbo...

Страница 9: ...e CATALYST reaches 80 percent of total battery capacity Low Battery Alert While running on battery a Low Battery alert chirps every 10 seconds and the OFF Button flashes when remaining capacity of the...

Страница 10: ...anisteriscompletelyfull theCATALYST turnsoff To change the canister 1 Clamp the tubing closed Figure 4 NOTE Only applicable if clamp is present If clamp is not present skip to the next step Figure 4 2...

Страница 11: ...ealthcare professional how to properly dispose of a used canister 6 To install a new canister hold the new unused canister at the bottom and slide upwards into the holder 7 Align the two ports and pre...

Страница 12: ...e than 2 hours in a 24 hour period Your dressing may need to be changed To disconnect from the CATALYST 1 Clamp the tubing closed Figure 4 NOTE Only applicable if clamp is present If clamp is not pres...

Страница 13: ...e front of the CATALYST Figure 10 OFF Button ON Button Figure 10 1 Press the ON Button All lights show for 1 second during the power on self test When finished the ON Button stays green Figure 11 Figu...

Страница 14: ...alert turn the CATALYST OFF then back ON The alert will clear when the power is cycled WHATYOU SEE HEAR 1 Low Pressure Leak BLINK Push up on bottom of canister Wait 30 seconds BEEP BLINK WHATTO DO 1 I...

Страница 15: ...Canister Full Blockage is fixed BLINK BLINK 9 Wait 1 minute BEEP Call Cardinal Health at 1 866 484 6798 SOLIDLIGHT WHATYOU SEE HEAR BLINK BEEP BLINK Canister Full Blockage First look at the canister t...

Страница 16: ...proceed with the steps below WHATTO DO Turn ON 2 1 Wait 30 seconds If you see If you see hear Canister Full Blockage is fixed Call Cardinal Health at 1 866 484 6798 SOLIDLIGHT BLINK BLINK BEEP Turn OF...

Страница 17: ...w battery fixed WHATYOU SEE HEAR 5 Intermittent Mode WHATTO DO CATALYST makes more noise every 5 minutes when in Intermittent Mode No troubleshooting needed For more information contact your healthcar...

Страница 18: ...fore cleaning The battery provides power when the CATALYST is unplugged so negative pressure wound therapy is not interrupted Clean the CATALYST with a damp soft cloth and a mild soap and water soluti...

Страница 19: ...eling and information to be supplied Authorized European Representative Indicates the Authorized Representative in the European Union ISO 15223 1 Clause 5 1 6 Medical devices Symbols to be used with m...

Страница 20: ...medical device labels labeling and information to be supplied Humidity Limitation Indicates the range of humidity to which the medical device can be safely exposed ISO 7000 2620 Graphical symbols for...

Страница 21: ...device that has been sterilized using irradiation ISO 7000 2502 Graphical symbols for use on equipment ISO 15223 1 Clause 5 2 5 Medical devices Symbols to be used with medical device labels labeling...

Страница 22: ...for use on equipment IEC 60878 5140 Graphical symbols for electrical equip ment in medical practice ISO 15223 1 Clause 5 3 9 Medical devices Symbols to be used with medical device labels labeling and...

Страница 23: ...ins or Presence of Natural Rubber Latex Indicatesthepresenceof naturalrubberordrynatural rubberlatexasamaterialof constructionwithinthe medicaldeviceorthe packagingofamedicaldevice EN 50419 Marking of...

Страница 24: ...s Protection Provided by Enclosure Protected against solid foreign objects of 1 0mm and greater and against the effects of continuous immersion in water IEC 60529 Degrees of protection provided by enc...

Страница 25: ...ed for Class II equipment according to IEC 61140 ISO 7000 2616 External cord connected External Cord Connected Indicates that device is connected to an external power source ISO 7000 5008 OFF power OF...

Страница 26: ...thetic latex This glove has been tested for resistance to permeation of various chemotherapy drugs per ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chem...

Страница 27: ...s on how to open pouch 1 Single Glove 1 Single Glove Contains a single glove TUV Listed Productiscertifiedunder TUV sListingandClassifi cationservicesandforTUV certificationsforCanadaand theUSA Device...

Страница 28: ...Hz 0 8Amp Max External Power Supply Output 15VDC 2Amp EnvironmentalConditions Note Storage and Operation Conditions do not apply to the Additional Parts Identified within Section 7 CATALYST Storage Co...

Страница 29: ...r in meter s 0 01 0 1 1 10 100 0 12 0 38 1 2 3 8 12 0 12 0 38 1 2 3 8 12 0 23 0 73 2 3 7 3 23 The CATALYST is intended for use in an electromagnetic environment in which radiated RF disturbances are c...

Страница 30: ...1000 4 3 3V rms 150kHz 80MHz 3V m 800MHz 2 5GHz 3V rms 3V m Portable and mobile RF communications equipment should be used no closer to any part of the CATALYST including cables than the recommended s...

Страница 31: ...LYST please contact your local Cardinal Health representative or Call Customer Service at 1 866 484 6798 Cardinal Health Waukegan IL 60085 www cardinalhealth com Alwaysconsultaphysicianandproductinstr...

Страница 32: ...020 Cardinal Health All Rights Reserved CARDINAL HEALTH the Cardinal Health LOGO KENDALL CATALYST TWIST N CONNECT SENSISKIN and SPEEDCONNECT are trademarks or registered trademarks of Cardinal Health...

Отзывы: