About Your Cardinal Health™ CATALYST™

Your doctor has chosen the Cardinal Health CATALYST™ to remove fluid from your wound by using carefully controlled 
suction. It is important, however, for you to carefully watch the wound and the CATALYST™ to make sure that it is working 
properly. Below is some important information and questions that you should ask your healthcare professional.

Things you need to know about your CATALYST

•  Do not allow the CATALYST™ to get wet. Clamp the tubing (if clamp is present) and disconnect from the canister if 

you take a bath or shower. 

•  Keep the CATALYST™ plugged in whenever possible to keep the battery fully charged. Always take the A.C. 

Power Adapter with you when you leave home.

•  Keep the CATALYST™ upright to avoid a false Canister Full/Blockage alert.
•  Keep the CATALYST™ turned on at all times unless there is bleeding from the wound or instructed by your 

healthcare professional.

•  Do not change the Pressure Settings on the CATALYST™ unless you are told to do so by your healthcare professional.

Things to ask your healthcare professional

•  How to tell if there is a problem with your CATALYST™ or dressing.
•  What to do if you have a problem or a leak with your dressing.
•  What to do if you notice bleeding from the wound.
•  What to do if you must take your dressing off.
•  What activities you can do while using the CATALYST™.
•  Who to call if you need help.
•  How to take care of your CATALYST™.

This CATALYST™ Patient User Manual is not a guarantee or warranty. It is intended only as an operational guide.  
For additional information and questions, please contact Cardinal Health Customer Service at 1.866.484.6798.
In order for the CATALYST™ to provide safe, reliable and proper performance, the following conditions must be met.  
Failure to comply with these conditions voids all pertinent warranties.

•  All assembly, operation, adjustment, modification, maintenance and/or repair must be carried out only  

by qualified personnel authorized by Cardinal Health.

•  The electrical outlets of the room in which the CATALYST™ is used complies with the appropriate national  

electrical standards.

•  The CATALYST™ must be used in accordance with this Patient User Manual and all associatedlabeling.

CAUTION: 

Federal law restricts the CATALYST™ for sale by, or on the order of, a physician. As with any prescription 

medical device, failure to follow product instructions or changing settings without the express direction and/or 
supervision of a trained clinical caregiver may lead to improper product performance and the potential for serious or 
fatal injury. 

Содержание CATALYST NPWT

Страница 1: ...1 Cardinal Health Negative Pressure Wound Therapy CATALYST Patient User Manual...

Страница 2: ...leak with your dressing What to do if you notice bleeding from the wound What to do if you must take your dressing off What activities you can do while using the CATALYST Who to call if you need help...

Страница 3: ...stem could result in physical hazards including delayed therapy electrocution and fire These hazards could result in injury or death WARNING Use only the Cardinal Health NPWT Occlusion Detection Dress...

Страница 4: ...ATALYST 7 2 2 Charging the Battery 8 2 3 Changing the Canister 10 2 4 Disconnecting from the CATALYST 12 3 Operating Instructions 13 3 1 On Off 13 3 2Troubleshooting 14 4 Care Cleaning 18 4 1 Disposal...

Страница 5: ...h NPWT Occlusion Detection Dressing or Kendall NPWT Incision Management Dressing over exposed blood vessels or organs The Cardinal Health NPWT Occlusion Detection Dressings and Kendall NPWT Incision M...

Страница 6: ...erash maybeaddedsignsofmoreseriouscomplicationsofinfection Extracareandattentionshouldbe givenifthereareanysignsofpossibleinfectionorrelatedcomplications Infectioncanbeserious Withorwithoutthe CATALYS...

Страница 7: ...Negative PressureWoundTherapy Incision Management Dressing Kit is a wound dressing kit to be used with Cardinal Health Negative PressureWoundTherapy NPWT CATALYST ALLY and ALLYTO GO systems K171499 Th...

Страница 8: ...2 Figure 2 3 When the CATALYST is connected to an outlet the green light next to the Plugged In symbol comes on Figure 3 If the battery is charging the yellow light next to the Battery Charging symbo...

Страница 9: ...e CATALYST reaches 80 percent of total battery capacity Low Battery Alert While running on battery a Low Battery alert chirps every 10 seconds and the OFF Button flashes when remaining capacity of the...

Страница 10: ...anisteriscompletelyfull theCATALYST turnsoff To change the canister 1 Clamp the tubing closed Figure 4 NOTE Only applicable if clamp is present If clamp is not present skip to the next step Figure 4 2...

Страница 11: ...ealthcare professional how to properly dispose of a used canister 6 To install a new canister hold the new unused canister at the bottom and slide upwards into the holder 7 Align the two ports and pre...

Страница 12: ...e than 2 hours in a 24 hour period Your dressing may need to be changed To disconnect from the CATALYST 1 Clamp the tubing closed Figure 4 NOTE Only applicable if clamp is present If clamp is not pres...

Страница 13: ...e front of the CATALYST Figure 10 OFF Button ON Button Figure 10 1 Press the ON Button All lights show for 1 second during the power on self test When finished the ON Button stays green Figure 11 Figu...

Страница 14: ...alert turn the CATALYST OFF then back ON The alert will clear when the power is cycled WHATYOU SEE HEAR 1 Low Pressure Leak BLINK Push up on bottom of canister Wait 30 seconds BEEP BLINK WHATTO DO 1 I...

Страница 15: ...Canister Full Blockage is fixed BLINK BLINK 9 Wait 1 minute BEEP Call Cardinal Health at 1 866 484 6798 SOLIDLIGHT WHATYOU SEE HEAR BLINK BEEP BLINK Canister Full Blockage First look at the canister t...

Страница 16: ...proceed with the steps below WHATTO DO Turn ON 2 1 Wait 30 seconds If you see If you see hear Canister Full Blockage is fixed Call Cardinal Health at 1 866 484 6798 SOLIDLIGHT BLINK BLINK BEEP Turn OF...

Страница 17: ...w battery fixed WHATYOU SEE HEAR 5 Intermittent Mode WHATTO DO CATALYST makes more noise every 5 minutes when in Intermittent Mode No troubleshooting needed For more information contact your healthcar...

Страница 18: ...fore cleaning The battery provides power when the CATALYST is unplugged so negative pressure wound therapy is not interrupted Clean the CATALYST with a damp soft cloth and a mild soap and water soluti...

Страница 19: ...eling and information to be supplied Authorized European Representative Indicates the Authorized Representative in the European Union ISO 15223 1 Clause 5 1 6 Medical devices Symbols to be used with m...

Страница 20: ...medical device labels labeling and information to be supplied Humidity Limitation Indicates the range of humidity to which the medical device can be safely exposed ISO 7000 2620 Graphical symbols for...

Страница 21: ...device that has been sterilized using irradiation ISO 7000 2502 Graphical symbols for use on equipment ISO 15223 1 Clause 5 2 5 Medical devices Symbols to be used with medical device labels labeling...

Страница 22: ...for use on equipment IEC 60878 5140 Graphical symbols for electrical equip ment in medical practice ISO 15223 1 Clause 5 3 9 Medical devices Symbols to be used with medical device labels labeling and...

Страница 23: ...ins or Presence of Natural Rubber Latex Indicatesthepresenceof naturalrubberordrynatural rubberlatexasamaterialof constructionwithinthe medicaldeviceorthe packagingofamedicaldevice EN 50419 Marking of...

Страница 24: ...s Protection Provided by Enclosure Protected against solid foreign objects of 1 0mm and greater and against the effects of continuous immersion in water IEC 60529 Degrees of protection provided by enc...

Страница 25: ...ed for Class II equipment according to IEC 61140 ISO 7000 2616 External cord connected External Cord Connected Indicates that device is connected to an external power source ISO 7000 5008 OFF power OF...

Страница 26: ...thetic latex This glove has been tested for resistance to permeation of various chemotherapy drugs per ASTM D6978 Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chem...

Страница 27: ...s on how to open pouch 1 Single Glove 1 Single Glove Contains a single glove TUV Listed Productiscertifiedunder TUV sListingandClassifi cationservicesandforTUV certificationsforCanadaand theUSA Device...

Страница 28: ...Hz 0 8Amp Max External Power Supply Output 15VDC 2Amp EnvironmentalConditions Note Storage and Operation Conditions do not apply to the Additional Parts Identified within Section 7 CATALYST Storage Co...

Страница 29: ...r in meter s 0 01 0 1 1 10 100 0 12 0 38 1 2 3 8 12 0 12 0 38 1 2 3 8 12 0 23 0 73 2 3 7 3 23 The CATALYST is intended for use in an electromagnetic environment in which radiated RF disturbances are c...

Страница 30: ...1000 4 3 3V rms 150kHz 80MHz 3V m 800MHz 2 5GHz 3V rms 3V m Portable and mobile RF communications equipment should be used no closer to any part of the CATALYST including cables than the recommended s...

Страница 31: ...LYST please contact your local Cardinal Health representative or Call Customer Service at 1 866 484 6798 Cardinal Health Waukegan IL 60085 www cardinalhealth com Alwaysconsultaphysicianandproductinstr...

Страница 32: ...020 Cardinal Health All Rights Reserved CARDINAL HEALTH the Cardinal Health LOGO KENDALL CATALYST TWIST N CONNECT SENSISKIN and SPEEDCONNECT are trademarks or registered trademarks of Cardinal Health...

Отзывы: