19
Terminal board connections
1-2
MOT
motor power supply (to change the sense of rotation select
RIGHT
or
LEFT
boom installation from the OPTIONS menu)
3-4
ENCODER
inputs
Bl-Gr
for the encoder signal
5-6
ENCODER
inputs
Gy-Yw
for the encoder signal
7
LCK
8-9
EMRG
Emergency stop button
10-11
AUX1
Potential free NO-contact indicating the status of the boom (separate power
supply
Vmax=30 Vac/dc: Imax=1A
) or the second radio channel. Selection is
carried out on the display
LCD1
.
12-13
AUX2
Potential free NO-contact indicating the status of the boom (separate
power supply
Vmax=30 Vac/dc: Imax=1A
) or for the activation of the courtesy
light. Selection is carried out on the display
LCD1
.
14
CMN
common for all inputs and outputs
15
LP
24 Vdc 25 W
output for warning lights intermittent activation (50%),
12,5 W
continuous activation
16
LED 24 Vdc 3 W
output for the boom lights (pre-wired)
17
CMN
common for all inputs and outputs
18
24 Vdc
controlled output, powering external loads
(1)
19
CMN
common for all inputs and outputs
20
24 Vdc
output, powering external loads
(1)
21
TA1
(N.O. contact) opening button
1
input
22
TA2
(N.O. contact) opening button
2
input
23
TC1
(N.O. contact) closing button
1
input
24
TC2
(N.O. contact) closing button
2
input
25
CMN
common for all inputs and outputs
26
TB
(N.C./8.2 k
Ω
) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
(2)
27
CP
(N.C./8.2 k
Ω
)
safety edge input. Opening this contact will provoke a travel
direction inversion of a few degrees during the closing stage and during the
opening stage
(2)
28
FS
(N.C./8.2 k
Ω
) The opening of this contact will block all movement, until the
obstruction has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing direction (only
with automatic reclosing enabled)
(2)
29
FI
(N.C./8.2 kΩ) safety and control devices in input (photocells invert the travel
direction when an obstruction is detected). Opening this contact will provoke a
travel direction inversion during closure due to the cutting in of the safety device
(2)
31 Mass conductor for radio receiver antenna
30 Pole conductor for radio receiver antenna (if an external antenna is fitted use a
coaxial type cable
RG58
with an impedance of
50
Ω)
B1
Signal buzzer "
via radio
" mode
BC
Battery charger card
LCD1
Display
F1
15A
blade fuse
(4)
(motor power protection)
F2
4A
blade fuse
(4)
(
24V
circuit protection)
F3
15A
blade fuse
(4)
(motor protection during battery operation)
F4
4A
blade fuse
(4)
(
24V
circuit protection during battery operation
)
Nota
(4)
These are
automotive
type blade fuses
(max. voltage
58V
)
J1
Battery connection
J2
Transformer secondary protection
J3
Emergency enable jumper
MM
Transmitter code memory module
P1
Menu navigation button (
)
P2
Programming and confirm button (
PROG./OK
)
P3
Menu navigation button (
)
R1
Radio frequency module,
433 MHz
for series
S4XX and S500
transmitters
32
CMN
common for the emergency buttons
33
EMRG1
(N.A.) ingresso pulsante per manovra di emergenza 1
34
EMRG2
(N.A.) ingresso pulsante per manovra di emergenza 2
ALL UNUSED NC CONTACTS MUST BE JUMPED
and consequently the correspond-
ing security device tests (
FI
,
FS
) must also be deactivated. If you want to activate the
FI, FS
test both the transmission and receiver parts of the security devices must be
connected to the binding post marked (
CTRL24Vdc
).
If the test is active there will be a 1 second delay between the command transmission
and movement of the boom.
• Switch on the power and make sure that
the indicator LEDs are in the following condition.
- L1
Power on
ON
- L2
Wrong battery connection
OFF
(3)
Indications on the display
at rest activated
- S1
Indicator for the blocking button
TB
(4)
TB
- S2
Indicator for the inverting photoelectric cells
FI
(4)
FI
- S3
Indicator for the stop photoelectric cells
FS
(4)
FS
- S4
Indicator for the safety edge
CP
(4)
CP
- S5
Indicator for the opening button
TA
TA
- S6
Indicator for the closing button
TC
TC
- S7
Indicator for the sequential command
TD
TD
If the
green power on LED "L1" doesn't light up
check the condition of the fuses
and the power cable connection at the transformer primary.
If
one or more of the safety indications "S1, S2, S3, S4" flash
check the con-
tacts of the relative security devices and check that the unused safety device
contacts have been bridged.
The indications
"S5, S6, S7"
change status on the display when the relative
command is activated, eg. pressing the button "
TA
" will change the status from
'at rest' to 'active'
(white characters on a black background).
Note
(1)
The total of the 2 external device outputs must not exceed
10W.
Note
(2)
The (N.C./8.2 kΩ) selection is carried out on the
LCD1
display.
Note
(3)
If this LED is "
ON
" invert the battery power cables immediately.
Note
(4)
If the security device has not been activated the indications on the display
are at rest. Make sure that when the security device is activated the
status is inverted (black characters on a white background).
00.000.007
TB FI
FS CP
TA TD
TC
07-06-13 15.35
S5
S6
S1
S3
S7
S2
S4
Collegamenti scheda base CC ELDOM24
CC ELDOM24
17.07.15
DI0555
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
CENTRALINA 1 MOTORE CC CON ENCODER
CTRL 24Vdc
CMN
CMN
TC2 (N.O)
CMN
TA2 (N.O)
TC1 (N.O)
LP
LED
OUT 24Vdc
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
L2
34
33
32
CMN
EMRG 1
EMRG 2
11
EMRG
CMN
TA1 (N.O)
F1
15A
15A
F3
F2
4A
4A
F4
15A
15A
J2
J1
R1
MM
30
31
CS 1470B
DC 0551
L1
P1
P2
P3
MM
24LC64
FI (N.C/8.2 kΩ)
TB (N.C/8.2 kΩ)
FS (N.C/8.2 kΩ)
CP (N.C/8.2 kΩ)
B1
BC
J3
Enable
Disable
1 2 3
J3
Pos.1 Pos.2
1 2 3
PROGRAM
00.000.007
TB FI
FS CP
TA TD
TC
LCD1
07-06-13 15.35
4A
4A
AUX2-2
AUX2-1
AUX1-2
8
9
10
AUX1-1
EMRG
24LC16
3
4
5
6
7
1
2
Yw
Wh
Gy
Gr
Bl
ENCODER
LCK
Bk
Rd
MOT