26
It is possible to memorise a maximum of
5 master
transponder tags
to access the
interface remotely and manage user codes.
• On the interface, move the dips of '
S1
' to
'
ON
' according to the following table
to
select the memory locations.
dip 1 dip 2 dip 3
dip 4
memory
ON
OFF
OFF
OFF
location 1
OFF
ON
OFF
OFF
location 2
OFF
OFF
ON
OFF
location 3
OFF
OFF
OFF
ON
location 4
ON
ON
ON
ON
location 5
• Move the tag near to the remote
transponder reader
• The interface will give confirmation by
sounding a '
beep
'.
If you have inserted an invalid master code the
interface will sound 5 consecutive
beeps
.
• Move jumper
J5
on the interface to
'
position 1
'.
• Press and hold down the button
P1
for
at least 2 seconds.
•
During the procedure the red led
L2
will
light up.
• The buzzer
B1
will sound '
beep
'.
• The user code memorisation procedure
will be activated with a time maximum
of 30 seconds.
Keypad
• Type the code to memorise into the keypad
(max. 6 digits) and press confirm "
*
".
The keypad will sound a two-second long
beep
with the green led lit.
The code has been accepted
3. Memorising user codes locally