The interface (printed circuit CS1464) is fitted with an indoor container and has a 12-way terminal board with the
following electrical connection:
-
12V ac/dc
between binding posts 1-2 with jumper "
J6
" in position "
2
";
- 24V ac/dc
between binding posts 1-2 with jumper "
J6
" in position
"1".
If the distance between the interface and the keypad/transponder is notable, you are
advised to use a 24 Vac/dc power supply
Led L1
lights up when the device is powered up.
The interface has four normally open relays which are marked CHA, CHB, CHC, and CHD.
• According to the distance between the interface and the keypad / transponder run the cable carrying
the power to the keypad and the serial line data.
Keypad DKS250T
• Connect the Faston cables:
FS1
black
to binding post "
11
";
FS2
red
to binding post "
12
" on the interface
(see numerical keypad installation fig. 5b)
Transponder DKSTPT
• Connect the transponder wires:
black
to binding post "
11
";
red
to binding post "
12
" on the interface
(see transponder installation fig. 4 dett. 12)
.
DKS1000R INTERFACE ELECTRICAL CONNECTION