25
Connecting the optional card "SCL"
• Insert the optional card "
A
" fig 19.
• Pass the card connection wires through the cable clamp "
B
" and then
through the opening "
C
" fig 18.
• Wire up and then insert the terminal blocks into the card "
A
"
OPTIONAL INTERFACE SCL
Once the card has been inserted into the connector “
J6
” on the
programmer the following functions become available:
1) traffic light control signals;
2) interface with the special infrared safety edge;
3) controlling the activation of garage lights or air circulation fans.
The power supply for the indicator lamps and the "
AUX
"
contact must be drawn from an external source.
If the card is not present or is not being used leave the “
Eout
” and “
CSPF
”
parameters set to the value “
0
” (page 20).
The traffic light and
CSPF
safety edge functions are enabled/disabled
separately one from the other.
The settings for the
AUX
output must be set directly on the
SCL
card
using the dedicated dip switches.
Terminal board description
1
+12 Vdc
power supply output for the special safety edge (max. 60 mA).
2
Signal input from the special safety edge.
3
0 Vdc
power supply for the special safety edge.
4-5
Potential free contact NO powering the fan/garage lights (
230 Vac 5A
)
6-7
Potential free contact NO powering the green external traffic light
signal (
230 Vac 5A
)
8-9
Potential free contact NO powering the red external traffic light
signal (
230 Vac 5A
)
10-11 Potential free contact NO powering the green internal traffic light
signal (
230 Vac 5A
)
12-13 Potential free contact NO powering the red internal traffic light
signal (
230 Vac 5A
)
Description dip-switch DS1
DIP1
ON
: enables management of the special safety edge
OFF:
disables management of the special safety edge (the security
device is always deemed to be at rest)
DIP2
ON
: the AUX contact remains closed until the door is completely shut
OFF
: the AUX contact is only activated once (for the time selected
in DIP3) each time the command
TAI
/
TAE
activates the door
DIP3
Only with DIP2=OFF
:
ON
: activates the AUX output for 30 seconds
OFF
: activates the AUX output for 3 seconds
Traffic light signal control
Green and red traffic light signals can be wired to the terminal board
(maximum of 4 lights); the power supply for the lights must be supplied
externally as the terminal board is only fitted with potential free switch
contacts. The function modes with their relative signals are laid out in the
table at the bottom of the page.
Controlling the safety edge
The safety edge has two sensors (each with a protruding three-wire cable)
fitted into the rubber profile. These wires should be connected in parallel
by joining the wires with the same colour and then connecting them to the
terminal board as follows:
terminal board 1 brown wires (power supply
+12 Vdc
)
terminal board 2 green wires (signal)
terminal board 3 white wires (power supply
0 Vdc
)
The safety edge is recognised by moving DIP1 to the “
ON
” position.
To economise on battery power during blackouts, power will not be routed
to the safety edge unless the door is moving.
The "
safety test
" is never carried out for this device.
Alarm indications
No ulterior indications will be given if there is a problem with the optional
SCL
card as the display on the programmer will allow you to verify
the status of the individual safety devices.
Scheda aggiuntiva
YPR124SCL00
10-11-2005
DC0402
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Scheda controllo semaforo/costa Fraba
(per GL124 A Mosfet)
CS1235
DC0402
4
5
6
7
8
9
1 2 3
ON
DS1
+12V
L1
10
11
12
13
1
2
3
R_I
G_I
R_E
G_E
AUX
0V SIGN
RX
TX
br
gr
wh
SB
STATUS
Contact R_I
Contact G_I
Contact R_E
Contact G_E
Door closed
open
open
open
open
Pre-flashing stage
intermittent
open
intermittent
open
Movement stage (opening/closing)
closed
open
closed
open
Door stopped but not completely closed
closed
open
closed
open
Door completely open (TAI command)
open
closed
closed
open
Door completely open (TAE command)
closed
open
open
closed
Problem with the optional card
closed
open
closed
open
Legend
SB
- shunt box
RX
- reception sensor
TX
- transmission sensor
L1
- power supply led
DS1
- selection dip-switch
Connection cable Tx-Rx lenses
wh
- white wire
gr
- green wire
br
- brown wire
21
22
20