11
Terminal board connections
1- 2
M1
power supply motor 1
3- 4
M2
power supply motor 2
5
CMN
common for all inputs and outputs
6
ELS
electric lock output (fed continuously)
12 Vdc
-
15 W
7-8
LC-CH2
Potential free contact for the activation of the courtesy light (separate
power supply
Vmax=30 Vac/dc: Imax=1A
) or the second radio channel.
Selection is carried out using jumper "
J5
"
9
LS
24 Vdc
3 W
output for an indicator light
10
LP
24 Vdc
25 W
output for warning lights
intermittent activation (50%),
12,5 W
continuous activation
11
24 Vdc
controlled output, powering external loads
(1)
12
CMN
common for all inputs and outputs
13
CMN
common for all inputs and outputs
14
24 Vdc
output, powering external loads
(1)
15
CMN
common for all inputs and outputs
16
FC1
(N.C.) gate
1
closing travel limit input
17
FA1
(N.C.) gate
1
opening travel limit input
18
FC2
(N.C.) gate
2
closing travel limit input
19
FA2
(N.C.) gate
2
opening travel limit input
20
CMN
common for all inputs and outputs
21
TAL
(NO contact) limited opening button input
22
TA
(NO contact) opening button input
23
TC
(NO contact) closing button input
24
TD
(NO contact) dynamic button input
25
CMN
common for all inputs and outputs
26
TB
(N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
(2)
27
CSP
(N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
(2)
28
FTCS
(N.C./8.2 kΩ) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled)
(2)
29
FTCI
(N.C./8.2 kΩ) safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of the
safety device
(2)
30
CMN
common for all inputs and outputs
31-32-33
Not connected
34 Outer conductor for radio receiver antenna.
35 Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable
RG58
with an impedance of
50
Ω
).
Note
(1)
The total of the 2 external device outputs must not exceed
10 W.
Note
(2)
The selection of the type of contact (N.C./8.2 kΩ) is carried out using parameter
"SC" on the six-figure display.
ALL UNUSED NC CONTACTS MUST BE JUMPED
and consequently the security
device test must also be deactivated (
FTCI
,
FTCS
- Dip 9 and Dip 10 "
OFF
").
If you want to activate the
FTCI, FTCS
test both the transmission and receiver parts
of the security devices must be connected to the binding post marked "
CTRL 24
Vdc
". If the test is active there will be a 1 second delay between the command
transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the following
condition.
- L1
Power on
ON
- L2
Wrong battery connection
OFF
(3)
- L3
Transmitter code programming indicator
OFF
- L4
Indicator for the blocking button "
TB
"
ON
(4)
- L5
Indicator for the inverting photoelectric cells "
FTCI
"
ON
(4)
- L6
Indicator for the stop photoelectric cells "
FTCS
"
ON
(4)
- L7
Indicator for the safety edge "
CSP"
ON
(4)
- L8
Indicator for the opening button "
TA
"
OFF
- L9
Indicator for the opening button "
TC
"
OFF
- L10
Indicator for the limited opening button "
TAL
"
OFF
- L11
Indicator for the sequential command "
TD/CH1
"
OFF
Note
(3)
If this LED is "
ON
" invert the battery power cables immediately.
Note
(4)
Check that the activation of the safety devices switches the corresponding
LEDs off.
If the
green power on LED "L1" doesn't light up
check the condition of the fuses
and the power cable connection at the transformer primary.
If
one or more of the safety LEDs do not light up
check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
B1
Signal buzzer "
via radio
" mode
D1
Six-segment LED display
DS1
Selection dip-switch
F1
4A
fuse (
24V
circuit protection)
F2
4A
fuse
(electric lock protection)
F3
4A
fuse (
24V
circuit protection during battery operation)
F4
10A
fuse
(motor power protection)
F5
10A
fuse (motor protection during battery operation)
J1
Battery connection
J2
Transformer secondary protection
J3
Radio channel selection
J4
Enable transmitter memorisation via radio
J5
Binding posts 7, 8 selection (courtesy light/CH2 via radio)
MM
Transmitter code memory module
P1
Programming button (
PROG
)
P2
Transmitter code memorization button (
MEMO
)
P3
Transmitter code cancellation button (
DEL
)
R1
Radio frequency module,
433 MHz
for
S449
transmitters
2
Collegamenti scheda base
PRG900
04-02-2013
DC0535
CENTRALINA 2 MOTORI CC
(con 6 display a led - selezione a dipswitch )
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
CMN
CMN
FTCI (N.C)
TD (N.O)
CMN
TA (N.O)
TC (N.O)
TB (N.C)
LP
CTRL 24Vdc
OUT 24Vdc
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
LC/CH2
CSER
5
6
1
2
M1
CMN
ELS 12V
LS
TAL (N.O)
FTCS (N.C)
P1
J1
B1
CS 1435
DC 0535
35
34
J4
R1
L9
L8
L6
L5
L10
L7
L4
P3
P2
L3
1 2 3 4 5 6 7 8
9
10 11 12 13 14
ON
DS1
1 2 3
J5
Pos.1 Pos.2
1 2 3
CSP (N.C)
L11
MM
D1
3
4
M2
Fuse F4A
Fuse F4A
F3
F1
25
26
27
28
29
30
31 32 33
EMRG1
EMRG2
CMN
CMN
FC1
FA
1
FC2
FA
2
CMN
CMN
Fuse F4A
F2
J3
BC
Fuse F10A
F4
J2
Fuse F10A
F5
L1
L2