70-00969-01 F
Powerheart® AED G3 Pro 9300P
2-6
Getting Started
Directions for use
The rechargeable battery is shipped half-charged. Charge battery fully
before using.
Note:
The battery charger (model 9044) is sold separately.
To charge the battery:
1.
Remove the rechargeable battery from the AED. The rechargeable
battery can be recharged only when removed from the Powerheart
AED G3 Pro.
2.
Plug the charger into an appropriate electrical outlet.
3.
Insert the charger cable into the rechargeable battery and ensure
the yellow LED above the rechargeable battery symbol is on.
Charging is complete when the yellow Charge LED goes out, and
the four green Fuel Gauge LEDs are continuously lit.
4.
Remove the charger cable from the battery when done charging.
Charging may be terminated early by removing the charger cable
from the battery. If the battery is charged for a minimum of 3
hours, the stated capacities will be met.
!
Caution: Incorrectly charged battery (model 9144).
If the yellow Charge LED blinks continuously, a charging error
occurred. Contact customer service in the event of a charging error.
Note:
It is recommended that you keep a spare, non-rechargeable
battery nearby. For longest battery life, when storing battery,
discharge half-way. Do not store for extended periods at high
temperature.
The Powerheart AED G3 Pro will first indicate
Low Battery
while
there is still sufficient charge remaining to perform at least one rescue.
It is recommended to recharge the battery as soon as practical after the
Low Battery
indication. It is considered normal operation for the
battery capacity gauge to show some remaining capacity when the
Low
Battery
indication first occurs.