15
Doc Version: 1.3 / Date: 29.04.2021
4.
Decommissioning
1.
Before putting the dispenser out of service we recommend a chemical cleaning if you want to keep it
out of service for a longer time.
2.
Flush the dispenser and canister with clean water.
3.
Let the dispenser suck in air and through this empty the internal liquid buffer of about 400ml.
Do NOT disconnect the intake line from the dispenser in order to suck air. The Linktech coupler system
has a check valve that prevents air sucking and by this the internal liquid buffer cannot be emptied.
4.
Disconnect the intake line and remove power plug from electrical socket.
5.
Pull handle to open tap and release internal pressure
6.
Unscrew the nozzle from the Dispenser and put it in the accessory box to make sure the nozzle is not
connected to the dispenser and can dry out easily during non-usage period.
Protect the dispenser against rain and dust and store it in a temperatures range between 0 °C and 60°C.