Carbine PLUS-4700 Скачать руководство пользователя страница 18

18

Power Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.5 Volts Negative Ground

Trigger Inputs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Grounded Pin Switch, Positive Pin Switch, 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Sensor Ground, 0.6 Volt Current Drop

Current Requirements   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less Than 15mA Armed or Disarmed

Timers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programmable Automatic Arming Timer

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programmable Rearming Timer

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Second RF Tamper Rearming Timer

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Second Zone Bypass Re-Activation Timer

Grounded Output Wire Capacity (White Wire)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mA

Siren Output Wire Capacity   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Amps

Channel 2 Pulsed Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300mA

Bypass Zones  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Zones

Transmitter Frequency   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434mHz

Digital Code Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68,000,000,000

Code Method  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Code Hopping

Transmitter Buttons   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No More than 4

Ignition Controlled Door Locking: 

(Door lock activation must be installed)

When programmed on in “Remote Feature Programming”, ignition controlled locking is active 3 seconds

after the ignition key is set the On position, the door locks will automatically become locked. When the

ignition key is turned to the Off position, the door locks will unlock.

Note: If a protected entrance (door) is opened when the ignition key is set to the On position, the door

locks will not lock. This protective measure can not be deleted.

Channel #2 Output: 

(If Installed)

Press and hold the Channel 2 activation button (

*

) for 2 seconds. The designated Channel 2 output 

wire from the alarm will become grounded for as long as the (

*

) button is pressed.

Dual-Zone Sensor Pre-Warning Indicator: 

(If Installed)

1. Close all protected entrances and place the alarm in an armed condition.

2. Rap the vehicles body panels to activate the pre-warning zone of any dual-zone type sensor.

3. When the pre-warning indicator is triggered, the horn/siren will beep 1 time.

Step 8: Speciality Feature and Optional Equipment Testing

Specifications

Содержание PLUS-4700

Страница 1: ...t to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Not...

Страница 2: ...ompartment to secure the siren Select a location that provides a direct sound path to the ground for maximum siren output Use the self tapping screws provided and secure the siren Connect the black wi...

Страница 3: ...First Vacant Socket For Use with ALA RPT Relay Pack Only See Optional Accessory Connection for proper wiring Gray Wire Pulsed Ground for Car Horn The gray wire is a pulsed ground output designed to a...

Страница 4: ...nnect the violet wire directly to the switched turn on wire at the dome light The violet wire connects to positive switched circuits only Second Vacant Socket The second vacant wire socket provides a...

Страница 5: ...rectly to the battery post for best operation of the alarm system For best current sensing capability from the alarm s current sensing circuit connect the red wire to the constant power wire coming fr...

Страница 6: ...otors Black Wire Unlock Red Wire Lock Orange Wire No Connection White Wire Lock Brown Wire Unlock Green Wire Lock Blue Wire Unlock Violet Wire 3 Pin Black Plug ALA DL1 Relay Pack Note Prewired Door Lo...

Страница 7: ...ne wire to lock and unlock the doors Example When the door lock controller sees a signal thru a resistor it will unlock If a signal is received without a resistor the doors will lock Some use 2 resist...

Страница 8: ...r Ground To 12V or Ground Driver s Door Rear Door Passenger Door Switch Door Lock Relay Control Module Lock Unlock 12V Must Add ALA984H Relay Drivers Door Switch Cut Unlock Remaining Doors Unlock Driv...

Страница 9: ...ection of this manual Gray Wire Ground when Armed Alarm Output 2 Pin Black Connector 87 87a 86 85 30 ACC START OFF IGN Cut Black Black Starter Starter Disable Wiring Using ALA RPS Relay Pack Using the...

Страница 10: ...e Plug Dual Zone Electronic Sensor Plug Applies to PLUS 4000 Only Red Wire 12 Volt Sensor Power Supply Green Wire Sensor Pre Warning Output Black Wire Sensor Ground Supply Blue Wire Sensor Alarm Trigg...

Страница 11: ...sert Red Wire into the First Socket Insert Black Wire into the Eighth Socket Black Wire 2 Button Power Trunk Activation Using Optional ALA RPT Relay Pack Dome Light Supervision Using Optional 30 Amp R...

Страница 12: ...on S t e p 2 S t e p 1 ON O S t e p 3 Turn On Ignition Flip the Override Switch On then Off 3 Times The siren will chirp 1 time You are now in the transmitter code programming mode The LED will be a s...

Страница 13: ...urn Off the Ignition The horn siren will emit 1 short chirp and 1 long chirp You are now out of the consumer transmitter code learning mode The LED is Off OFF S t e p 5 Lock Unlock Panic Aux Regular T...

Страница 14: ...ion output Output Timing 2 Beeps 3 5 second duration output 5 Passive Arm 1 Beep Allows the door lock to lock when the alarm automatically Locking Control arms 2 Beeps Delayed auto arm locking is ON D...

Страница 15: ...horn siren and the parking lights will flash a second time The shock sensor function is now Off and will return to normal function at the next occurrence when the alarm is manually armed Note 1 If th...

Страница 16: ...ing On the ignition key the override function will be locked out Place the override switch in the Off position turn Off the ignition key and try again Last Door Automatic Arming If Programmed On Note...

Страница 17: ...ypassed Four chirps Tamper indicator alarm is disarmed Power Door Lock Unlock If Installed 1 Press the LOCK button on the transmitter the locks will become locked 2 Press the UNLOCK button on the tran...

Страница 18: ...on controlled locking is active 3 seconds after the ignition key is set the On position the door locks will automatically become locked When the ignition key is turned to the Off position the door loc...

Страница 19: ...Connection Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Override Socket Blue Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switched 12V Red Wire To Battery 12V Au...

Страница 20: ...PLUS 4700 IM 11 19 03 Rev A Copyright 2004 Magnadyne Corporation R...

Отзывы: