docs.carbide3d.com
10/02/2020
Version 1.0
29
Install the Proximity Switch Mounts
Install the X- and Z-Axis Proximity Switch Mounts
Required Components:
Item
Description
Qty
D
X-Axis Proximity Switch Mount
1
E
M5 × 25mm Socket Head Cap Screw
2
J
Z-Axis Proximity Switch Mount
1
K
M4 × 6mm Button Head Cap Screw
1
1.
Install the X-Axis proximity switch mount to the
back of the HDZ. See
Fig. 28
and
Fig. 28 inset
.
a.
Align the mounting slots with the two M5
screw holes on the Y2-side of the X-motor.
b.
The two gold-colored threaded inserts on
the mount face out (away from X-motor).
c.
Use a 4mm hex key and two (2)
M5
×
25mm SHCS to secure.
d.
Before fully tightening the screws, slide
the mount toward the X-motor far as it
will go.
2.
Install the Z-Axis proximity switch mount to the
back of the HDZ. See
Fig. 28
.
a.
Align the mount with the M4 screw hole
at the very top of the HDZ.
b.
Use a 2.5mm hex key and one (1) M4
×
6mm BHCS to secure the mount at the top of the HDZ.
Figure 28