3

 

 
2>. Under the compressor is running normally, if only one zone no cooling, the fault 

should happen on the part in this zone.(two zones have the same structure, so the 
maintain method for them are same). 
a.

 

Check the valve by hearing the sound. turn off the wine cooler and exchange the 

connectors of the valve then power on, listen carefully you can hear the snip-snap 
sound from valve, otherwise the valve is power off or broken or the PCB fault. 
Confirming the PCB is normal, replace the valve.

 (

8)

 (Fig.9)

 

 

b. If the valve is running normally, it maybe the capillary jam, please clean it 
with nitrogen, you can overhaul it refer to above. 
c. 

Replace the fault spear parts. Confirming the cooling system is not jammed, refill 

the refrigerant.

 

 

Refill 

1>.

  Using  the  vacuum  pump  form  a  vacuum  in  the  system,  via  the  joint  of  the  low-pressure  pipe

 

(Fig.4,see point A)

the high-pressure pipeline is on the process pipe of the filter

Apply the vacuum 

pump  for  approximately  20  minutes.  Until  the  vacuum  is  lower  than  100Pa.  Then  solder  the  process 

pipe of the filter    Keep the the system vacuum. 

 
2>.

 Fill Cooling system  with refrigerant via the process pipe

 (Fig.4,see point A)

. The refrigerant 

and  quantity  Please  refer  to  the  instruction  at  back  label  of  wine  cellar.  Then  solder  the  compressor 

process pipe after the system is charged with refrigerant. 

 

 

Test 

Replace all the components after the procedures above and turn the unit on. To verify the effectiveness 

of  the  repair,  monitor  the  unit,  the  compressor  should  automatically  stop  when  both  zone  1.5

  lower 

than setting temperatures and start when either zone 2.5

 higher than setting temperature

 within 

approx 3 hours (assuming an ambient temperature of 32

and the unit is empty).

 

 

 

How to remove the air-duct boards 

 

  1>. Pull the shelves to the bottom, circumvolve any side of the right and left, and let the setter of the shelve go 

out of the channel, and then draw out the shelves. 

  (Fig.1)

 

 

Содержание WI6225

Страница 1: ...WI6225 Caple 60cm 2 Door Wine Cabinet Technical information...

Страница 2: ......

Страница 3: ......

Страница 4: ...or 2 13 DG7 3 1 BH Evaporator fan 2 14 DG22 209 Air duct board 2 15 DG19 1 Fan cover 2 16 DG13 198 Senser cover 2 17 DG8 8 Senser 2 18 DG3 12 W LED Light 2 19 DG13 383 Display holder 2 20 DG20 256 Dis...

Страница 5: ...le 60cm 2 Door Wine Cabinet 33 DG14 167 BL Lower hinge module Left 1 34 DG12 91 2 Condenser 1 35 DG13 6 11 Cabinet leg 4 36 DG12 113 Air circulating pipe 2 37 DG22 80 2 Compressor bracket 1 38 DG14 56...

Страница 6: ......

Страница 7: ...ry protection well When servicing the wine cooler with R600a systems please make sure the ambient is well ventilated Preparation before maintenance Tools 1 Plier 2 Cross screwdraver 3 Assistant pipe 4...

Страница 8: ...cooler and check the current again check the discharge pipe of the compressor at the same time if it has an clear air pressure if the electricity is still too high or has not air pressure it shows th...

Страница 9: ...pressure pipeline is on the process pipe of the filter Apply the vacuum pump for approximately 20 minutes Until the vacuum is lower than 100Pa Then solder the process pipe of the filter Keep the the s...

Страница 10: ...ews need not to remove and remove the air duct board Be attention to unplug the connection wire when removing the air duct board You can move slowly aside until you can see the fans wire and unplug th...

Страница 11: ...ant pipe soldered jointed B Anti dew pipe soldered joint C Right zone suction pipe soldered joint D Discharge pipe soldered joint E Left zone suction pipe soldered joint F Condenser soldered joint G F...

Страница 12: ...the fan s fault the reason is following a The axletree of the fan broken b The bad balance because the fans abrasion 3 The fan can be replace with another same model s fan the procedure is following a...

Страница 13: ...ency impact noise in capillary Zone Caused by either Causation 1 The capillary being insert too deep into the evaporator so when the refrigerant is Jetting the end of vibrating capillary will hit the...

Страница 14: ...t fix for the door Fig 7 The instability of the wine cooler temperature The unstable temperature is caused by the evaporator fans cease and it can be check by the below method When the compressor is r...

Страница 15: ...ion wire and the main board whether short circuit if not replace the sensor with the same module See Fig 8 6 The LED display shows HI and it is the high temperature protection indication After running...

Страница 16: ...ht is normal and another zone is not cooling or over low temperature lower than the temperature preset 3 or one zone is not cooling the other zone is over cold please check the refrigerant valve 2 Tur...

Страница 17: ...trical box in right zone disconnect all connectors remove the main PCB The process of display PCB removed remove the shelves take apart the inner electrical box disconnect all connectors if necessary...

Страница 18: ...ers on display board supporter 8 as per arrowhead direction and then remove the display board and its two connectors from both sides Replace the display board See Fig 11 Fig 12 The name and explanatio...

Страница 19: ...compressor 7 To the valve 8 To the main PCB white 9 To the condenser fan Red 10 To the transformer secondary How to remove the power PCB and transformer The process of power PCB removed remove the el...

Страница 20: ...replace the LED light The process of LED light removed remove all shelve in the zone take apart the inner electrical box disconnect light connector if necessary remove the main PCB remove the LED ligh...

Отзывы: