  Noise problem 

     

 

Compressor noise

 

            1>. The working of motor and piston motion will cause noise when compressor working. So if noise is steady 

and not exceeds 42 dB, it

s normal. If noise is not steady or very high, it

s compressor fault and it should 

be maintained or replaced. 

 

2>.  If  compressor

s  shock  absorption  rubber  is  hardening  or  damaged,  or  fixing  screw  of  compressor  is  too 

tight  or  loose,  it  will  cause  noise.  The  settlement  is  to  change  new  shock  absorption  rubber  or  adjust 

fixing screws. 

 

 

Fan noise

 

     

1>. The running of the fan motor will cause noise because the vane circumvolve in high speed and the airflow. 

Normal fan motor and airflow should not exceed 32 dB.

 

 

   

    2

>. If the noise is extremely big , there maybe the fan

s fault, the reason is following: 

a.

 

The axletree of the fan broken 

b.

 

The bad balance because the fans abrasion 

 

3

>. The fan can be replace with another same model

s fan, the procedure is following: 

a.

 

How to replace the evaporator fan . 

The process of evaporator fan removed: Remove the shelves

remove the airduct board

disconnect the connectors

remove the fan cover remove the fan.

 

                1>. Remove the shelves. 

(

3) (Fig.1)   

2> . Remove the air duct board. See

 (

3) (Fig.2) 

3>. Remove screws

A

B

C

D

then replace the evaporator fan See 

(Fig.2 & Fig.5)

 

 

                                                                                                                                                                             

 

b. How to replace the condenser fan: 

1>. Remove the screws(3,4) ,take apart the electrical box

A

;

(Fig.6)

 

                          2>. Pull off    the of the fan connector on the power PCB.

 (Fig.13)

 

3>. Lean back the cabinet 45

0

, or put it on the workbench, and use a Set of cross-screwdriver to wrest 

off the two screws(1,2) of compressor bottom penal, and remove the condenser fan to replace with a new one.

 

(Fig.6 & Fig.6.1)   

 

Fig. 5 

Содержание WI6225

Страница 1: ...WI6225 Caple 60cm 2 Door Wine Cabinet Technical information...

Страница 2: ......

Страница 3: ......

Страница 4: ...or 2 13 DG7 3 1 BH Evaporator fan 2 14 DG22 209 Air duct board 2 15 DG19 1 Fan cover 2 16 DG13 198 Senser cover 2 17 DG8 8 Senser 2 18 DG3 12 W LED Light 2 19 DG13 383 Display holder 2 20 DG20 256 Dis...

Страница 5: ...le 60cm 2 Door Wine Cabinet 33 DG14 167 BL Lower hinge module Left 1 34 DG12 91 2 Condenser 1 35 DG13 6 11 Cabinet leg 4 36 DG12 113 Air circulating pipe 2 37 DG22 80 2 Compressor bracket 1 38 DG14 56...

Страница 6: ......

Страница 7: ...ry protection well When servicing the wine cooler with R600a systems please make sure the ambient is well ventilated Preparation before maintenance Tools 1 Plier 2 Cross screwdraver 3 Assistant pipe 4...

Страница 8: ...cooler and check the current again check the discharge pipe of the compressor at the same time if it has an clear air pressure if the electricity is still too high or has not air pressure it shows th...

Страница 9: ...pressure pipeline is on the process pipe of the filter Apply the vacuum pump for approximately 20 minutes Until the vacuum is lower than 100Pa Then solder the process pipe of the filter Keep the the s...

Страница 10: ...ews need not to remove and remove the air duct board Be attention to unplug the connection wire when removing the air duct board You can move slowly aside until you can see the fans wire and unplug th...

Страница 11: ...ant pipe soldered jointed B Anti dew pipe soldered joint C Right zone suction pipe soldered joint D Discharge pipe soldered joint E Left zone suction pipe soldered joint F Condenser soldered joint G F...

Страница 12: ...the fan s fault the reason is following a The axletree of the fan broken b The bad balance because the fans abrasion 3 The fan can be replace with another same model s fan the procedure is following a...

Страница 13: ...ency impact noise in capillary Zone Caused by either Causation 1 The capillary being insert too deep into the evaporator so when the refrigerant is Jetting the end of vibrating capillary will hit the...

Страница 14: ...t fix for the door Fig 7 The instability of the wine cooler temperature The unstable temperature is caused by the evaporator fans cease and it can be check by the below method When the compressor is r...

Страница 15: ...ion wire and the main board whether short circuit if not replace the sensor with the same module See Fig 8 6 The LED display shows HI and it is the high temperature protection indication After running...

Страница 16: ...ht is normal and another zone is not cooling or over low temperature lower than the temperature preset 3 or one zone is not cooling the other zone is over cold please check the refrigerant valve 2 Tur...

Страница 17: ...trical box in right zone disconnect all connectors remove the main PCB The process of display PCB removed remove the shelves take apart the inner electrical box disconnect all connectors if necessary...

Страница 18: ...ers on display board supporter 8 as per arrowhead direction and then remove the display board and its two connectors from both sides Replace the display board See Fig 11 Fig 12 The name and explanatio...

Страница 19: ...compressor 7 To the valve 8 To the main PCB white 9 To the condenser fan Red 10 To the transformer secondary How to remove the power PCB and transformer The process of power PCB removed remove the el...

Страница 20: ...replace the LED light The process of LED light removed remove all shelve in the zone take apart the inner electrical box disconnect light connector if necessary remove the main PCB remove the LED ligh...

Отзывы: