
INSTALLATION - False Drywall Chimney Breast & Twin Wall Flue
13
8. Locate the Frameless Kit onto the fire box and
secure the fire box and the frame kit to the wall using
the fixing holes provided in the frame and fire box.
9. Cut and fix drywall boards to the framework of the
chimney breast ensuring they fit neatly around the
flange of the Frame Kit (Fig. 25).
10. The chimney breast must have adequate
ventilation, minimum of 200cm
2
. The room will utilise
warm air flow if a vent is fitted at the top and bottom of
the chimney breast as shown in Fig (Fig. 25).
11. Locate the drywall trim surround into the opening
and secure using the attached magnets (Fig. 25).
Frameless Kit
Drywall Board
Vents Minimum (200cm
2
)
Drywall Trim
Surround
Frameless Kit fitted
on front of wall
surface
20mm slips fitted on
to wall surface
Fig. 24
Fig. 25
Fig. 26
Fig. 27
Содержание Designline DL400
Страница 2: ......
Страница 33: ...9 10 7 8 11 SPLIT LOG LAYOUT DL700 DL800 CONTINUED 33 ...
Страница 38: ...SERVICE NOTES 38 ...
Страница 39: ...SERVICE NOTES 39 ...