Canon
varioPRINT 6000 TITAN Series Service Guide
varioPRINT 6000 TITAN Series
Service Guide
April 2021
Revision 1
Page 34
Table 28 – Power and Plug Requirements
Part or Accessory
Power Supply
Power Receptacle
Main Unit (Print Engine Module)
(Select only ONE outlet configuration)
3 Phase
208-240 V/30 A outlet
NEMA L15-30R
Single Phase
208-240 V/50 A outlet
NEMA 14-50R
Paper Input Module (each)
115 V/15 A outlet
NEMA 5-15R
High Capacity Stacker Only (each)
115 V/15 A outlet
NEMA 5-15R
High Capacity Stacker
with Set Finisher
115 V/15 A outlet
NEMA 5-15R
Media Enhancement Module
100-240 V/15 A outlet
NEMA 5-15R
PRISMAsync Print Server
Powered by the Main Unit
N/A
Print Guard Unit
115 V/20 A outlet x 2
NEMA 5-20R x 2
GBC PowerPunch
110 V/20 A outlet
NEMA 5-20R
DFS30-N Tape Binder
110 V/20 A outlet
NEMA 5-20R
BLM6200 (formerly the BLM200)
120 V/15 A outlet
NEMA 5-20R
BLM6300
120 V/15 A outlet
NEMA 5-20R
200–240 V / 16A 50/60Hz outlet
NEMA 6-20R
Book Stacker
From the BLM 550+
Booklet Maker
N/A
Watkiss P2T 2-Knife Trimmer
200–240 V / 16A 50/60Hz outlet
NEMA 6-20R
BGB3202 Perfect Binder
(Select only ONE outlet configuration)
3 Phase
208-240 V/30 A outlet
NEMA L6-30R
3 Phase
208-240 V/30 A outlet
NEMA 14-30R
3 Phase
208-240 V/30 A outlet
NEMA L15-30R
BGB3202 Compiler
120 V / 3A - 60 Hz outlet
NEMA 5-15R
BGB3202 Leman Dust Collector
120 V / 3A - 60 Hz outlet
NEMA 5-15R
Videk DocuVision Edge
(Select only ONE outlet configuration)
120 V/15 A outlet
NEMA 5-15R
200-240 V/5 A outlet
NEMA 6-15R
53 The Set Finisher is powered by the IIM 208V AC.
54 If the Print Guard units are installed, the customer must provide two, 115V AC, 20 amp, dedicated, single phase lines. If a
finisher is attached, the customer must supply a separate 208V AC, single phase, 20 amp line.
55 Two outlets are required for a system with one stacker, and three outlets are required for a system with two stackers.
56 The BGB3202 Perfect Binder can only be configured as a 220 V system.