CHAPTER 6 ERROR CODES
6-5
No.
T/R
Description
NEW##671 R
at time of V.8 arrival, procedure fails to move to phase 2 after detection
of CM signal from caller, causing T1 time-out and releasing line
NEW##672 T
at time of V.34 transmission, procedure fails to move from phase 2 to
phase 3, causing T1 time-out and releasing line
NEW##673 R
at time of V.34 reception, procedure fails to move from phase 2 to phase
3, causing T1-time-out and releasing line
NEW##674 T
at time of V.34 transmission, procedure fails to move from phase 3 or
phase 4 to control channel, causing T1 time-out and releasing line
NEW##675 R
at time of V.34 reception, procedure fails to move from phase 3 or
phase 4 to control channel, causing T1 time-out and releasing line
##750 T
Exceed Repeat Protocol Due to Failure to Receive Significant Signals
after Transmitting PPS-NULL during ECM Transmission
##752 T
Receive DCN after PPS-NULL Transmission During ECM
Transmission
##753 T
Exceed Protocol Retransmission Limit or T5 Time (60 seconds) after
PPS-NULL transmission during ECM Transmission
##754 T
Exceed Retransmit Protocol after PPS-NULL Transmission during
ECM Transmission
##755 T
Exceed Protocol Retransmission Limit Due to Failure to Receive
Significant Signals after PPS-MPS Transmission during ECM
Transmission
re-transmissions
##757 T
Receive DCN after PPS-MPS transmission during ECM Transmission
##758 T
Exceed Protocol Retransmission Limit or T5 Time (60 seconds) after
PPS-MPS Transmission during ECM Transmission
##759 T
Exceed Retransmit Protocol after PPS-MPS Transmission during ECM
Transmission
##760 T
Exceed Protocol Retransmission Limit Due to Failure to Receive
Significant Signals after PPS-EOM Transmission during ECM
Transmission
##762 T
Receive DCN after PPS-EOM Transmission during ECM Transmission
##763 T
Exceed protocol Retransmission Limit or T5 Time (60 Seconds) after
PPS-MPS Transmission during ECM Transmission
##764 T
Exceed Retransmit Protocol after PPS-EOM Transmission during
ECM Transmission
##765 T
Exceed Protocol Retransmission Limit Due to Failure to Receive
Significant Signals after PPS-EOP Transmission during ECM
Transmission
##767 T
Receive DCN after PPS-EOP Transmission during ECM Transmission
Содержание Super G3 Fax Board-J1
Страница 84: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 CHAPTER 6 ERROR CODES ...
Страница 94: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 APPENDIX ...
Страница 106: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 A 12 Blank Page ...
Страница 109: ...PRINTEDINU S A 0601MX XX 1 This publication is printed on 100 recycled paper ...