COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SUPER G3FAX BOARD-J1 REV.0 JUNE 2001
CHAPTER 5 SERVICE MODE
5-15
#1 SSSW-SW12: page timer setting
Bit
Function
1
0
Factory setting
0
Time-out period for one page upon 1
0
0
transmission
1
1
0
1
2
Time-out period for one page upon 1
0
0
transmission (HT transmission)
3
1
0
0
4
Time-out period for one page upon 1
0
0
reception
5
1
0
0
6
not used
0
7
Respective page timer settings for enable
do not enable
0
transmission and for reception
The machine will stop the ongoing communication if the transmission/reception of a
single original page takes 32 min or more. To use the timer for a purpose other than this
function, refer to the tables that follow, and select an appropriate time length.
When ‘disable’ is selected using bit 7, the time-out length for a single page for all modes
will depend on the setting of bit 0 and bit 1.
Содержание Super G3 Fax Board-J1
Страница 84: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 CHAPTER 6 ERROR CODES ...
Страница 94: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 APPENDIX ...
Страница 106: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON SUPER G3 FAX BOARD J1 REV 0 JUNE 2001 A 12 Blank Page ...
Страница 109: ...PRINTEDINU S A 0601MX XX 1 This publication is printed on 100 recycled paper ...