4
4
4-28
4-28
Parts Replacement and Cleaning Procedure > Main Units > Removing the Stapler Drive Unit
Parts Replacement and Cleaning Procedure > Main Units > Removing the Stapler Drive Unit
Removing the Stapler Drive Unit
1) Remove the stapler unit.
2) Remove the Grate-shaped
lower guide.
3) Release the harness for the stapler drive unit from the 3 wire saddles, and then remove 2 connectors (10P and 2P).
x2
x2
F-4-54
F-4-54
4) Remove the 2 screws and open the finisher controller
PCB mount.
x2
F-4-55
F-4-55
5) Disconnect the sensor connector and release the motor harness from the 2 wire saddles and the edge saddle.
Disconnect the motor connector and release the motor harness from the wire saddle.
F-4-56
F-4-56
Содержание Staple Finisher-D1
Страница 4: ...0 0 0 4 0 4 ...
Страница 9: ...Safety Precautions Notes Before it Works Servicing ...
Страница 11: ...1 1 Product Outline Product Outline Features Specifications Names of Parts Optional Construction ...
Страница 59: ...3 3 Periodic Servicing Periodic Servicing List of Work for Scheduled Servicing ...
Страница 144: ...5 5 Adjustment Adjustment Overview Basic Adjustment Action on parts replacement ...
Страница 194: ...7 7 Appendix Appendix Service Tools General Circuit Diagram F 7 1 F 7 1 ...