5
5
5-5
5-5
Adjustment > Basic Adjustment > Stack Delivery Upper Roller Ascension Timing Adjustment
Adjustment > Basic Adjustment > Stack Delivery Upper Roller Ascension Timing Adjustment
Stack Delivery Upper Roller Ascension Timing
Adjustment
Overview
Adjustment of the stack delivery upper roller ascension timing when stacking the buffered
paper (A4/LTR/B5, 2 or 3 sheaves of paper) to the processing tray unit.
Purpose of Adjustment
To correct the paper alignment at the sort and staple sort mode.
How to enter the adjustment mode
(1) Turn on the power with all SW3 keys set to OFF.
(2) Set the SW3 keys as shown below and press the SW1 continuously for two seconds.
ON
1 2 3 4
A4
ON
1 2 3 4
LTR
ON
1 2 3 4
B5
Adjustment Method
(1) The LED1 and LED2 indicate the current adjustment value.
(2) Pressing the SW1 reduces the value by 1 ms.
Pressing the SW2 increases the value by 1 ms.
(3) The LED1 and LED2 light for 500 ms.
(4) The LED1 and LED2 indicate the new adjustment value.
Repeat steps (2) to (4) until the desired adjustment value is displayed.
(5) Pressing the SW1 continuously for two seconds writes the new adjustment value to the
EEPROM.
Pressing the SW2 continuously for two seconds cancels the new adjustment value.
(Be sure to cancel the new adjustment value before writing it to the EEPROM.)
(6) The LED2 goes out and the LED1 blinks at intervals of 0.5 seconds.
(7) Set all SW3 keys set to OFF.
•
•
•
F-5-8
F-5-8
F-5-9
F-5-9
F-5-10
F-5-10
Adjustment Range
The stack delivery upper roller[1] ascension timing can be increased up to 50 ms. (It
hastens the ascension timing of the swing guide.) [Default: 0 ms]
[1]
Display of Adjustment Value
- The numbers of times the LED1 and LED2 blink indicate the adjustment value assuming
that the LED1 stands for a tens digit and the LED2 stands for a units digit. Each LED blinks
at intervals of 300 ms.
(If the LED1 blinks 2 time and the LED2 blinks 4 times, the adjustment value is 24 ms (= 10
x 2 + 1 x 4). )
- Each LED stays lit for two seconds to indicate 0 (zero).
Example: Display of the adjustment value “24 ms”
Turn*
LED1
LED2
Remarks
Tens
digit
1
*(Blinks 2
times)
○
Blinking interval: 300 ms.
2
○
○
LED1/LED2 stays unlit. (1 second)
Units
digit
3
○
*(Blinks 4
times)
Blinking interval: 300 ms.
4
○
○
LED1/LED2 stays unlit. (1 second)
○= Stays unlit, ●= Stays lit, *= Blinking
*: It repeats from the turn 1 to 4 during the adjustment value indication.
•
•
F-5-11
F-5-11
T-5-4
T-5-4
Содержание Staple Finisher-D1
Страница 4: ...0 0 0 4 0 4 ...
Страница 9: ...Safety Precautions Notes Before it Works Servicing ...
Страница 11: ...1 1 Product Outline Product Outline Features Specifications Names of Parts Optional Construction ...
Страница 59: ...3 3 Periodic Servicing Periodic Servicing List of Work for Scheduled Servicing ...
Страница 144: ...5 5 Adjustment Adjustment Overview Basic Adjustment Action on parts replacement ...
Страница 194: ...7 7 Appendix Appendix Service Tools General Circuit Diagram F 7 1 F 7 1 ...