![Canon SmartBase MPC400 Скачать руководство пользователя страница 126](http://html.mh-extra.com/html/canon/smartbase-mpc400/smartbase-mpc400_service-manual_2552579126.webp)
4-42
SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
5.2.5 New SSSWs/parameters added to this model
#1 SSSW (service soft switch setting)
SW01 (service soft switch 01: error management)
Bit
Function
1
0
0
Service error code
Output
Not output
1
Error dump list
Output
Not output
2
Not used
3
Copy function
No
Yes
4 (New) ##300 series service error code
Output
Not output
5
Not used
6
Not used
7
User setting restriction
Setting possible
Setting restricted
[Bit 4]
Even when Bit0 is set to "Not output", you can select whether or not to output ##300 series Service
Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Service Error Codes are displayed and in reports.
When "Not Output" is selected, no Service Error Codes are displayed.
#1 SSSW (service soft switch setting)
SW15 (service soft switch 15: Dial-in FAX/TEL switching function setting)
Bit
Function
1
0
0
Not used
1
Not used
2
Not used
3
Not used
4
Not used
5
Not used
6 (New) Detect continuous signal at
Yes
No
FAX/TEL switching
7
Not used
[Bit 6]
You may enable or disable detection of ROT continuous signal for FAX/TEL switching.
Normally, only ROT intermittent signals are detected for FAX/TEL switching. If you need to
detect both in view of exchange specifications, select to enable detection.
Содержание SmartBase MPC400
Страница 5: ...III III REVISION HISTORY REVISION CONTENT 0 Original ...
Страница 9: ...Chapter 1 General Description ...
Страница 10: ......
Страница 29: ...Chapter 2 Technical Reference ...
Страница 30: ......
Страница 47: ...Chapter 3 Assembly and Disassembly ...
Страница 48: ......
Страница 82: ......
Страница 83: ...Chapter 4 Maintenance and Service ...
Страница 84: ......
Страница 146: ...4 62 SmartBase MPC600F MPC400 Chapter 4 Maintenance Service Figure 4 27 Print Pattern Sample ...
Страница 159: ...4 75 SmartBase MPC600F MPC400 Chapter 4 Maintenance Service Figure 4 32 System Data List 2 6 ...
Страница 160: ...4 76 SmartBase MPC600F MPC400 Chapter 4 Maintenance Service Figure 4 33 System Data List 3 6 ...
Страница 161: ...4 77 SmartBase MPC600F MPC400 Chapter 4 Maintenance Service Figure 4 34 System Data List 4 6 ...
Страница 162: ...4 78 SmartBase MPC600F MPC400 Chapter 4 Maintenance Service Figure 4 35 System Data List 5 6 ...
Страница 170: ......
Страница 171: ...Chapter 5 Appendix ...
Страница 172: ......
Страница 178: ......
Страница 179: ...1101 AT CANON INC ...