Océ 31x5E Copy jobs & daily maintenance
Safety data sheet Océ 3145 Digital Copier
The content of this safety data sheet is subject to the disclaimer of liability on page 103 of this manual.
PRODUCT SAFETY DATA SHEET
Number
E-704-a-US
Date
July 1999
Copyright © 1999 Océ-Technologies B.V., Venlo, NL
Model
Océ 3145 DC
Description
Electrostatic digital copier, console model, plain paper, organic photoconductive belt,
powder toner, automatic duplexing.
Max. process speed
46 A4 copies/min or 23 A3 copies/min
Dimensions
Width
1622 mm
Depth
885 mm
Height
1280 mm
Weight
413 kg
Voltage
120 V
208 V
220-240 V
Frequency
60 Hz
60 Hz
60 Hz
Current-rated
16 A
9,8 A
9,2-8,8 A
Current-max
20 A
14 A
14 A
Power consumption, operation
2000 W
Power consumption, standby
560 W
Mains connection
Cable with plug
Safety class
I
(IEC 536) Protective earth connection
Protection class
IP 20
(IEC 529)
Sound pressure level
(at operator/bystander
position)
Standby:
In operation:
38 dB(A)
mainbody 59 dB(A);
incl. optionals 60 dB(A);
impulse
∆
L
i
= 5 dB(A)
Sound power level
49 dB(A)
mainbody 72 dB(A); incl. optionals 74 dB(A)
Radio interference
Complies with FCC r ules and regulations, part 15 class A
Radiation
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Heat emission
Standby 560 W ; in operation 2000 W
Ozone emission
0,01 mg/min at continuous operation
Room volume
Recommendation: min. 30 m
3
Room ventilation
Recommendation: min. 15 m
3
/h (natural ventilation)
For heat evacuation extra ventilation may be necessary.
Use simulation at random
operation
Room volume and ventilation as recommended
Daily copy volume (much more than average)
7500 A4
Total worktime
8 h
Ozone concentrations:
- Time weighted average
0,001 mg/m
3
(0.0005 ppm)
- Peak
0,003 mg/m
3
(0.0015 ppm)
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone
0,04 mg/m
3
(0,02 ppm)
Consumables
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F11 Toner (Océ Material Safety Data Sheet E-212)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281.
Additional safety information
The ozone Þlter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m (the life of the Þlter equals that of the apparatus).
3
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
Содержание oce 31x5e
Страница 1: ...Océ 31x5E Copy jobs daily maintenance ...
Страница 4: ...4 Océ 31x5E Copy jobs daily maintenance ...
Страница 8: ...8 Océ 31x5E Copy jobs daily maintenance ...
Страница 44: ...44 Océ 31x5E Copy jobs daily maintenance ...
Страница 91: ...91 Océ 31x5E Copy jobs daily maintenance Appendix A Overview and tables ...
Страница 99: ...99 Océ 31x5E Copy jobs daily maintenance Appendix B Safety information ...
Страница 128: ...128 Océ 31x5E Copy jobs daily maintenance ...
Страница 129: ...129 Océ 31x5E Copy jobs daily maintenance Appendix C Miscellaneous ...