2–24
STANDARDS AND ADJUSTMENTS
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS10
Right door open/closed sensor
(RDOP*)
J309-12
No. 220
1-f
Open the right door while in
standby.
When the right
door is opened
0
—
When the right
door is not
opened
1
—
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS12
Vertical path roller 2 paper sensor
(VP2P)
J309-5
—
Open the right door, and push the
sensor flag.
PS11
Copyboard cover open/closed
sensor (CVOP)
J310-A11
—
Open and close the copyboard
cover.
When the
copyboard
cover is closed
1
5V
When the
copyboard cover
is opened
0
0V
When the
sensor flag is
pushed
1
5V
When the sensor
flag is not
pushed
0
0V
PS13
Cassette 2 paper sensor (CPD2*)
J309-3
—
Slide out the cassette 2 while in
standby.
When the
cassette is slid
out
0
–
When paper is
placed in the
cassette and the
cassette is slid in
1
–
Содержание NP6621
Страница 4: ...ii ...
Страница 8: ...vi ...
Страница 48: ...3 2 IMAGE FAULTS ...
Страница 49: ...3 3 IMAGE FAULTS NOT USED ...
Страница 50: ...3 4 IMAGE FAULTS B Image Fault Samples not available ...
Страница 80: ...4 16 TROUBLESHOOTING MALFUNCTIONS ...
Страница 98: ...6 8 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS D PCBs Figure 6 603 1 2 3 4 5 6 7 8 9 10 11 12 ...
Страница 108: ...6 18 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 4 Fixing Heater Driver PCB Figure 6 611 J402 1 J401 W1 W2 ...
Страница 134: ...A 4 APPENDIX ...
Страница 135: ...A 5 APPENDIX C GENERAL CIRCUIT DIAGRAM not available ...
Страница 136: ...A 6 APPENDIX ...
Страница 144: ...A 14 APPENDIX ...