11-102
CHAPTER 11 TROUBLESHOOTING
COPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
B. Troubleshooting Malfunctions in the Pedestal
1
E901
Cause
Pedestal motor
(M1)
Pedestal
controller PCB
DC controller
PCB
Checks
Set the meter to the 100VDC
range, and measure the voltage
between J109-1 (+; PEDMD) and
J109-4 (-) on the pedestal
controller PCB.
Does the voltage change to about
5 V when WMUPR starts after the
power switch has been turned on?
Replace the pedestal controller
PCB. Is the problem corrected?
Step
1
2
YES/NO
YES
YES
NO
Action
Replace the pedestal
motor.
End.
Check the wiring from
the DC controller PCB to
the pedestal controller
PCB; if normal, replace
the DC controller PCB.