4) Turn the flat-blade screwdriver in the direction of arrow
e
to open the electrode plate
in the direction of arrow
r
, and remove the scanning lamp
t
.
Figure 4-302
1. If the scanning lamp is hot, wait until it has cooled.
2. Do not leave fingerprints on the scanning lamp.
3. If the surface of the scanning lamp is soiled, dry wipe it.
2. Orientation of the Scanning Lamp
Orient the scanning lamp
q
so that the protrusion in its middle points in the direction
of the arrow (direction in which the mirror mount moves in reverse); for lengthwise
orientation, keep the logo mark facing the front.
Figure 4-303
When installing the scanning lamp, avoid touching its surface.
4-26
CHAPTER 4 IMAGE FORMATION SYSTEM
COPYRIGHT © 1997 CANON INC. CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)