Table 4-7-2
CHAPTER 4 SERVICE MODE
4-11
No.
320
321
322
323
324
325
326
Description
Arch adjustment when cassette
2 is used (pick-up roller OFF
timing)
Arch adjustment when cassette
2 is used (pick-up roller OFF
timing)
Arch adjustment when cassette
2 is used (pick-up roller OFF
timing)
Pick-up clutch (CL2) off timing
adjustment
Cassette 2 pick-up clutch
(CL1cu) off timing adjustment
Cassette 3 pick-up clutch
(CL2cu) off timing adjustment
Scanning lamp intensity
adjustment
Remarks
A higher setting increases the arch.
default: 25
unit:
0.27 mm
A higher setting increases the arch.
default: 25
unit:
0.27 mm
A higher setting increases the arch.
default: 25
unit:
0.27 mm
For factory only
default: 32
For factory only
default: 20
For factory only
default: 20
For factory only
default: 75
Settings
0 ~ 63
0 ~ 63
0 ~ 63
0 ~ 63
0 ~ 63
0 ~ 63
0 ~ 76
Содержание NP6218
Страница 5: ...1 1 1 CHAPTER 1 MAINTENANCE AND INSPECTION A Image Adjustment Basic Procedure ...
Страница 6: ...1 2 B Periodical Servicing ...
Страница 48: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 2 A Sensors Figure 3 1 ...
Страница 50: ...B Clutches Solenoids and Switches Figure 3 2 CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 4 ...
Страница 52: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 6 C Motors Heaters and Lamps Figure 3 3 ...
Страница 54: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 8 D PCBs Figure 3 4 ...
Страница 60: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF THE ELECTRICAL PARTS 3 14 ...
Страница 76: ...CHAPTER 4 SERVICE MODE 4 16 ...
Страница 84: ...CHAPTER 5 SELF DIAGNOSIS 5 8 ...
Страница 87: ...A 3 C GENERAL CIRCUIT DIAGRAM not available ...
Страница 88: ...A 4 ...